GATT

 

UUID 

UUID_Device Information 

0000180A-0000-1000-8000-00805F9B34FB 

UUID_Firmware Revision String   

00002A26-0000-1000-8000-00805F9B34FB 

UUID_NOTIFY (~20 bytes) 

00031234-0000-1000-8000-00805F9B0130 

UUID_RxData (~20 bytes) 

00031234-0000-1000-8000-00805F9B0131 

UUID_MacID (6 bytes) 

00031234-0000-1000-8000-00805F9B0133 

UUID_DeviceName (15 bytes) 

00031234-0000-1000-8000-00805F9B0134 

UUID_Reboot (1 bytes) 

00031234-0000-1000-8000-00805F9B0135 

UUID_PinID_Setting (6 bytes) 

00031234-0000-1000-8000-00805F9B0136 

UUID_BLE_CONF (7 bytes) 

00031234-0000-1000-8000-00805F9B0132 

 

Byte0 

Byte1

 

Byte2

 

Byte3

 

Data bit 

Hwfc 

Stop Bit 

Parity Bit 

7,8 

0x01:on 

0x00:off 

2:1 

3:1.5 

4:2 

0x02 : No Parity 

0x01 : Odd Parity 

0x00 : Even Parity 

 

Byte4

 

Byte5

 

Byte6

 

Baud Rate 

Device Mode 

Reset To Default 

00:9600 

01:19200 

02:38400 

03:57600 

04:115200 

05:230400 

06:2400 

07:4800 

08:1200 

09

460800 

10

921600 

0x01:on 

0x00:off 

0x01: Reset 

 

 

6. Command set via COM port: 

Command 

Value 

Description 

AT 

 

Check the connection status between control terminal and the RS-232 
adapter. Response: “OK” when the connection is ok. Response: 
“ERROR” when the connection is not ok. 

AT 

 

Test the RS-232 status when first connect the adapter with the controller. 

(Default) 

The command will disable the auto link function. 

 

Inquire the current setting. 

BAUD= 

 

This command is used to specify the baud rate of COM port. 
The command will need 200 ms delay. 

 

1200 

1200 bps 

Summary of Contents for BLE-485C

Page 1: ...Weight 105 g Package Contents BLE 422 485 adapter x 1 Screw x2 Screw nut x 2 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data...

Page 2: ...cter 2 The GATT service and AT command will support more settings than the DIP switch please check the page 4 section 5 and page 5 section 6 3 Power supply 3 1 Voltage 5 27 VDC Don t exceed the limit...

Page 3: ...radio only 0 dbm 4 7 Operation Temperature 40 C to 70 C 4 8 Dimensions 81 6 mm L x 31 75 mm W x 17 mm H 4 9 Antenna Gain max 2 dB Remark All contents are subject to change without notice 5 GATT Servi...

Page 4: ...e1 Byte2 Byte3 Data bit Hwfc Stop Bit Parity Bit 7 8 0x01 on 0x00 off 2 1 3 1 5 4 2 0x02 No Parity 0x01 Odd Parity 0x00 Even Parity Byte4 Byte5 Byte6 Baud Rate Device Mode Reset To Default 00 9600 01...

Page 5: ...choed back to the DTE DCE Default Y Command characters received from the UART are echoed back to the DTE DCE Inquire the current setting FLOW This command enable or disable flow control signals CTS RT...

Page 6: ...hanged the adaptor will reboot and all paired addresses will be cleared C Set the adaptor to the central role Default P Set the adaptor to the peripheral role Inquire the current role of the adaptor S...

Page 7: ...al Then select the other one as the peripheral and link The central will link with the neighboring peripheral automatically The blue LED will be solid on The central will link with the paired peripher...

Page 8: ...BLE RS 485 Serial Adapter user manual V1 1 8 APP Download Android iOS APP Sample code Please contact the supplier for the test sample code...

Reviews: