2.2 Rear Side: 

             

 

 

Switch configuration: 

Setup 

CTS/RTS 

Unused  Parity 

Role 

Baud Rate 

7-6 

3-2-1 

0: by APP or 

Command   

1: by Switch 

0: Disable 

1: Enable 

 

0: None 

1: Even 

0:

 

Peripheral 

1: Central 

(Auto link with 

peripheral) 

110:2400 

111:4800 

000:9600 

001:19200 

010:38400 

011:57600 

100:115200 

101:230400 

Remark:   

1. “000000000” by default, in 

red bold

 character 

2. The GATT service and AT command will support more settings than the DIP switch, please 

check the page 4 section 5 and page 5 section 6. 

 

 

2.3 DB9 connector (Male) 

 

DIP Switch 

  DCE 

  DTE 

2: RX        7: RTS 
3: TX        8: CTS 
5: GND    9: VCC 

Summary of Contents for RS-232

Page 1: ...ight 100 g Package Contents BLE V5 0 RS 232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data LED solid on No data t...

Page 2: ...None 1 Even 0 Peripheral 1 Central Auto link with peripheral 110 2400 111 4800 000 9600 001 19200 010 38400 011 57600 100 115200 101 230400 Remark 1 000000000 by default in red bold character 2 The GA...

Page 3: ...package 4 Specifications 4 1 Default value Baud rate 9 600 bps Data bit 8 Parity none Stop bit 1 Flow control none Device Name BLE232 Pin code None Fast pairing 4 2 Serial Port Baud Rate 1 2 2 4 4 8...

Page 4: ...BLE5DATA 00031201 0000 1000 8000 00805f9b0130 Data from BLE232_TxData Notification UUID_BLE5SENT 00031202 0000 1000 8000 00805f9b0130 Data to BLE232_RxData max244bytes package write only UUID_BLE5CONF...

Page 5: ...Address 6bytes read write UUID_BLE5NAME 00031205 0000 1000 8000 00805f9b0130 Device name Max 15bytes UTF 8 read write UUID_BLE5PIN 00031206 0000 1000 8000 00805f9b0130 Pin code 6bytes read write UUID...

Page 6: ...efault device name xx xx xx xx is a character string with the length from 2 to 30 R Restore the default settings name BLE Serial Inquire the name of the local adaptor PARITY This command is used to sp...

Page 7: ...AT command Please refer to page 5 section 6 The DIP 9 on the default setting 0 Set role c or ROLE C in one adapter The central will link with the neighboring peripheral automatically The blue LED will...

Page 8: ...BLE V5 0 RS 232 adapter user manual V1 6 2020 08 14 8 Download Please contact the supplier for the APP download or the sample code Android iOS Send data Receive data...

Reviews: