10
CLEANING PROCEDURES
3) Using a clean eye dropper insert 1 tablespoon of hydrogen peroxide or common
household bleach into the yellow tube. This will flow into the tank once water is
turned back on to unit. Reattach yellow tube to the ball valve. Follow startup
procedure and drain two full tanks of water.
Then, replace carbon Post-filter.
1) Turn off the water supply to your RO system at the angle stop adapter and open the
RO faucet to drain the storage tank.
Sanitization procedure must be performed before
a filter change.
Note:
2) Disconnect the yellow tube from the ball valve on the storage tank.
3) Once all water in the tank is purged, check air pressure using an air pressure gauge, it should read between
8-10 PSI. (Digital air pressure gauge is recommended)
CHECK AIR PRESSURE IN STORAGE TANK
Important:
Check air pressure only when tank is empty of water!
1) Turn off the incoming water supply to the RO.
2) Open the RO Faucet and allow water to drain from the tank until it is
completely empty.
Check air pressure in the storage tank when you notice a decrease in available water from the RO system. Air
can be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind
the blue plastic cap.
Tip:
When water from the RO faucet slows to a trickle, with the faucet still in the open
position, you may add air to the tank to purge any left over water, this will ensure that the tank is
completely empty.
4) Follow startup procedure.
•
A maintenance record should be kept for the RO system, including information about the
replacement parts, when service was performed, and by whom.
•
It is recommended that you completely drain the RO Tank every month.