6
STEP 2: TAPPING INTO COLD WATER LINE
Caution: The water supply to your unit MUST be from the COLD WATER LINE.
Hot water will severely damage your R.O. System.
1) Locate cold water angle shut off valve underneath the
sink and turn it off. Open cold water faucet to release
the pressure. On single handled faucets, the hot water
may have to be turned off to prevent any hot water cross
over. If water continues to come out of faucet with angle
valves turned off, the house main will have to be turned
off.
2) Locate the angle stop adapter in the installation kit.
3) Disconnect the cold water supply line from the angle
stop water valve and install the Angle Stop Adapter
as pictured.
Angle Stop Adapter - 09-9160
Connect Male Threaded
end to Cold Water
Supply Line
Connect Female Threaded
end to Cold Water Angle
Stop Valve
A
B
To Kitchen Faucet
Cold Water
Angle Stop Valve
Angle Stop
Adapter
Cold Water
Supply Line
A
B
5) Insert the open end of the orange 1/4” tube into the open 1/4” quick connect
fitting on the plastic angle stop adapter valve making sure the tube is
pushed in all the way, past the O-ring to the tube stop.
Orange Tube
Angle Stop Adapter
4) In the parts bag, locate the 1/4” orange tube. Connect the tube to
the elbow fitting on the back of the RO Module labeled “IN” making
sure the tube is pushed in all the way to the tube stop.