background image

IMP117-10

www.ueonline.com

CP12113500

U N I T E D   E L E C T R I C   
C O N T R O L S

180 Dexter Avenue, P.O. Box 9143
Watertown, MA  02471-9143   uSA
Telephone: 617 926-1000    Fax: 617 926-2568
http://www.ueonline.com

RECOMMENDED PRACTICES AND WARNINGS 

United  Electric  Controls  Company  recommends  careful  consideration  of  the 
following  factors  when  specifying  and  installing  UE  pressure  and  temperature 
units. Before installing a unit, the Installation and Maintenance instructions pro-
vided with unit must be read and understood. 

•  To avoid damaging unit, proof pressure and maximum temperature limits stat-

ed in literature and on nameplates must never be exceeded, even by surges in 
the system. Operation of the unit up to maximum pressure or temperature is 
acceptable on a limited basis (e.g., start-up, testing) but continuous operation 
must  be  restricted  to  the  designated  adjustable  range.  Excessive  cycling  at 
maximum pressure or temperature limits could reduce sensor life.

•  A back-up unit is necessary for applications where damage to a primary unit 

could endanger life, limb or property. A high or low limit switch is necessary 
for applications where a dangerous runaway condition could result.

•  The  adjustable  range  must  be  selected  so  that  incorrect,  inadvertent  or 

malicious setting at any range point cannot result in an unsafe system con-
dition.  

•  Install unit where shock, vibration and ambient temperature fluctuations will 

not  damage  unit  or  affect  operation.  When  applicable,  orient  unit  so  that 
moisture  does  not  enter  the  enclosure  via  the  electrical  connection.  When 
appropriate, this entry point should be sealed to prevent moisture entry.

•  Unit must not be altered or modified after shipment. Consult UE if modifi-

cation is necessary.  

•  Monitor  operation  to  observe  warning  signs  of  possible  damage  to  unit, 

such as drift in set point or faulty display.  Check unit immediately.

•  Preventative maintenance and periodic testing is necessary for critical appli-

cations where damage could endanger property or personnel.

•  Electrical ratings stated in literature and on nameplate must not be exceed-

ed. Overload on a switch can cause damage, even on the first cycle.  Wire 
unit according to local and national electrical codes, using wire size recom-
mended in installation sheet.

•  Do not mount unit in ambient temp. exceeding published limits.

LIMITED WARRANTY

Seller  warrants  that  the  product  hereby  purchased  is,  upon  delivery,  free  from 
defects in material and workmanship and that any such product which is found to 
be defective in such workmanship or material will be repaired or replaced by Seller 
(Ex-works,  Factory,  Watertown,  Massachusetts.  INCOTERMS);  provided,  however, 
that  this  warranty  applies  only  to  equipment  found  to  be  so  defective  within  a 
period of 24 months from the date of manufacture by the Seller. Seller shall not 
be obligated under this warranty for alleged defects which examination discloses 
are due to tampering, misuse, neglect, improper storage, and in any case where 
products  are  disassembled  by  anyone  other  than  authorized  Seller’s  representa-
tives.  EXCEPT  FOR  THE  LIMITED  WARRANTY  OF  REPAIR  AND  REPLACEMENT 
STATED  ABOVE,  SELLER  DISCLAIMS  ALL  WARRANTIES  WHATSOEVER  WITH 
RESPECT  TO  THE  PRODUCT,  INCLUDING  ALL  IMPLIED  WARRANTIES  OF 
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

LIMITATION OF SELLER’S LIAbILITY

SELLER’S LIABILITY TO BUYER FOR ANY LOSS OR CLAIM, INCLUDING LIABILITY 
INCURRED  IN  CONNECTION  WITH  (I)  BREACH  OF  ANY  WARRANTY  WHATSO-
EVER, EXPRESSED OR IMPLIED, (II) A BREACH OF CONTRACT, (III) A NEGLIGENT 
ACT OR ACTS (OR NEGLIGENT FAILURE TO ACT) COMMITTED BY SELLER, OR (IV) 
AN  ACT  FOR  WHICH  STRICT  LIABILITY  WILL  BE  INPUTTED  TO  SELLER,  IS  LIM-
ITED TO THE “LIMITED WARRANTY” OF REPAIR AND/OR REPLACEMENT AS SO 
STATED IN OUR WARRANTY OF PRODUCT.  IN NO EVENT SHALL THE SELLER BE 
LIABLE FOR ANY SPECIAL, INDIRECT, CONSEqUENTIAL OR OTHER DAMAGES OF 
A LIkE GENERAL NATURE, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS 
OR PRODUCTION, OR LOSS OR EXPENSES OF ANY NATURE INCURRED BY THE 
BUYER OR ANY THIRD PARTY.

UE specifications subject to change without notice.

Summary of Contents for 117 Series

Page 1: ...ustable Wrench Screwdriver Hammer for alternate wire knockouts Mounting WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS Install unit where shock vibration and temperature fluc tuations are minimal mount unit so that moisture is pre vented from entering the enclosure IF UNIT IS BEING installed where heavy condensation ...

Page 2: ...6 HEX HEAD SCREW INSTALLED IN THE 1 4 HEX PLUNGER THE LENGTH OF THIS ASSEMBLY IS ADJUSTED AT OUR FACTORY AND IS CRITICAL TO THE FUNCTION OF THE CONTROL DURING NORMAL ADJUSTMENT THESE COMPONENTS SHOULD NOT BE DISTURBED Do not adjust unless re gapping is necessary For set point adjustments and recalibration connect control to a calibrated pressure source Remove cover Loosen Phillips screw adjustment...

Page 3: ...TH COVER 101 6mm CLEARANCE FOR 1 4 6 35mm SCREW 2 MT G HOLES 895 22 7mm DIA KNOCK OUT 2 PLACES 2 75 69 9mm KNOCK OUT 2 75 ADJUSTMENT SCREW Dimension A Models Inches mm NPT Pressure 171 174 7 63 193 8 1 2 183 186 483 486 7 56 192 0 1 2 188 189 488 489 6 63 168 4 1 2 190 194 490 494 6 63 168 4 1 2 218 6 56 166 6 1 4 358 376 7 00 177 8 1 4 520 525 8 44 214 4 1 2 530 535 8 00 203 2 1 2 560 564 6 63 16...

Page 4: ...or critical appli cations where damage could endanger property or personnel Electrical ratings stated in literature and on nameplate must not be exceed ed Overload on a switch can cause damage even on the first cycle Wire unit according to local and national electrical codes using wire size recom mended in installation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARR...

Reviews: