COMBUSTION TEST - OPTIONAL NITRIC OXIDE SENSOR
Instructions for C165 Analyzers fitted with optional Nitric Oxide (NO) sensors
Displaying the Nitric Oxide (NO) reading
Select “Menu” on the rotary switch and navigate using the function buttons:
Select SCREEN and then select AUX
Choose a line to display the required readings as below
AUX display
The AUX (auxiliary) display can be customized via MENU / SCREEN / AUX.
The parameters displayed on lines 1, 2, 3, 4, 5 and 6 can be set by the user.
They remain the AUX parameters until changed by the user.
NOTE:
To EXIT the MENU at any time simply move the rotary switch to any position other than MENU . Any changes that have not been “entered”
will be ignored .
Use
◀
/
◀
to navigate to the main menu option SCREEN . Press
.
Use
◀
/
◀
to navigate to the sub menu option AUX . Press
.
The display will show
Press
and a third line will appear .
Use
◀
/
◀
to navigate to the desired parameter to be displayed on line 1 .
Press
to select the parameter for Line 1 and repeat the process to select the display parameter for all four lines and then EXIT . Rotate the dial
from MENU to AUX to display all your chosen settings .
PRINTING and STORING
The NO readings are printed and stored in the same way as the other combustion gas readings . On the printouts the NO readings appear directly
below the flue CO readings .
The dial needs to be in the AUX, Flue 1 or Flue 2 positions to print or store flue combustion readings . When the dilution pump is operating to protect
the CO sensor the NO readings are also affected by an unspecified amount . The screen will typically show: