23
f
urnACes
(
Continued
): A
tmosPHeriC
, g
As
& o
il
n
AturAl
g
As
& P
roPAne
Verify proper combustion:
• O2
• CO
• Stack Temp
• Vent Pressure
• Efficiency
Test
• Limit Switch
• Pressure Switch
Set Up
• Gas Pressure
Verify proper:
• Static Duct Pressure
• Temperature Rise
• AC side Static Pressure Drop across coils
o
il
f
urnACe
Verify proper combustion:
• O2
• CO
• Stack Temp
• Stack Draft
• Efficiency
Test & Verify:
• Smoke
Set Up
• Over Fire Draft
Verify proper
• Static Duct Pressure
• Temperature Rise
• AC side Static Pressure Drop across coils
A
tmosPHeriC
f
urnACe
Draft
Verify proper
• Temperature Rise
• AC side Static Pressure Drop across coils
Verify proper combustion:
• O2
• CO
• Stack Temp
• Efficiency