WARRANTY
The C162/C163/C164 combustion analyzer is warranted for one year including sensors. If within the
warranty period your instrument should become inoperative from such defects, the unit will be repaired
or replaced at UEi’s option. This warranty covers normal use and does not cover damage which occurs
in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or
improper maintenance (calibration). Batteries and consequential damage resulting from failed batteries
are not covered by warranty. Any implied warranties, including but not limited to implied warranties
of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall
not be liable for loss of use of the instrument or other incidental or consequential damages, expenses,
or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase
receipt or other proof of original purchase date will be required before warranty repairs will be rendered.
Instruments out of warranty will be repaired (when repairable) for a service charge. Warranty only covers
hardware and does not extend to software applications or accessories. Contact UEi for specific warranty
and service information.
UEi Test Instruments • 1-800-547-5740 • info@ueitest.com
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.
Download the full
Owners Manual at
UEiTEST.COM or
SCAN THIS CODE
POST TESTING
BATTERIES
The analyzer is fitted with 3
(AA) size rechargeable batter-
ies. Observe correct polarity
when replacing.
Always check operation
immediately after battery
replacement.
Do not leave batteries in unit for
extended periods of non-use.
WARNING
Do not recharge with Alkaline
batteries fitted. Alkaline batteries
are not rechargeable. Attempting
to recharge alkaline batteries
may result in product damage
and create a fire risk.
Time and Date will need to be
reset after changing batteries.
Always dispose batteries using
approved disposal methods that
protect the environment.
Remove the probe from the flue and
allow analyzer to purge with fresh
air until readings return to zero. O2
to 20.9% and CO below 20 ppm
CAUTION:
probe tip will be HOT.
POWERING OFF
When you power off the Analyzer, there is a 10 second purge.
CAUTION
Make sure you do not exceed the analyzer’s operating specifications.
• Do not exceed the flue probes maximum temperature (1112˚F)
• Do not exceed the analyzer’s internal temperature range 112°F (50°C)
• Do not put the analyzer on a hot surface
• Do not exceed the water trap’s level
• Do not let the particle filter become dirty and blocked