background image

C165+ Q

uiCk

 S

tart

 G

uide

Combu

stion Analy

zer

C165+

CO

  C

O2

  T

EM

PR

S

Status

L I N K

v3

Aux

O2/Eff

CO/CO2

Temp

Exch Test

ROOM CO  

BACKED BY

1-800-547-5740 • Fax: (503) 643-6322

www.ueitest.com • Email: info@ueitest.com

Summary of Contents for C165+

Page 1: ... Quick Start Guide Combustion Analyzer C165 CO CO 2 T E M P P R S Status L I N K v3 Aux O2 Eff CO CO2 Temp Exch Test ROOM CO BACKED BY 1 800 547 5740 Fax 503 643 6322 www ueitest com Email info ueitest com ...

Page 2: ... Status L I N K v3 Aux O2 Eff CO CO2 Temp Exch Test ROOM CO C165 OVERVIEW Sensors Fitted CO NO CO H2 CO2 O2 Serial No UEiTEST INSTRUMENTS www ueitest com Tel 1 800 547 5740 T2 T1 P2 P1 Q M A D B C E F P N T S U R I L J G K O H Top View Bottom View ...

Page 3: ... Particle Filter inside water trap K LED Water Trap Indication LED is active while the pump is on to bring user awareness to any condensate building up in the water trap L Grip Indentation Indentation for fingers to grip analyzer M Water Trap Drain Plug Red plug take caution NOT to damage plug when removing protective boot N Serial Number QR Code O Sensors Fitted label under Protective Boot Indica...

Page 4: ...of field Press Button to enter content and move to next field MENU SCREEN C165 START UP STATUS SCREEN Rotate Selector Dial to STATUS to view parameters Ta ATM CAL DATE TIME BATTERY LEVEL Change Fuel Type With the first line selected press and ARROW BUTTONS to change currently selected Fuel NAT GAS H OIL PELLETS mmHG PSI kPA PA mmH2O mBar Press Button to select Combustion Analyzer C165 CO CO 2 T E ...

Page 5: ...ampling ambient FRESH air AUXILIARY SCREEN The AUX screen allows you to assign any of the following parameters on any display line CO2 CO NO if fitted NOx if fitted O2 TF Ti Ta Delta T Loss EFg Xair Ra CO CO2 Ratio PI Fuel Type PRS or Blank To customize the settings displayed on screen Rotate dial to Scroll or to SCREEN Press Scroll or to AUX Press Scroll or to select the line to change Press High...

Page 6: ...ff to view CO2 O2 Efgc T1 Ta Status Bar NAT GAS Fuel type can be changed via or STATUS setting Rotate selector dial to CO CO2 to view CO COa LOSS XAIR O2 P Status Bar NAT GAS Fuel type can be changed via or STATUS setting Make any adjustments as needed for proper combustion and wait for analyzer to display change in readings Repeat as necessary T2 T1 P2 P1 Once complete remove probe from stack all...

Page 7: ... combustion probe or true draft probe tip in the flue to measure draft Connect static pressure hose to measure differential pressure T2 T1 P2 P1 PRESSURE TEST Combustion Analyzer C165 CO CO 2 T E M P P R S Status L I N K v3 Aux O2 Eff CO CO2 Temp Exch Test ROOM CO TEMPERATURE TEST Rotate the selector dial to PRS TEMP T2 T1 P2 P1 T2 T1 P2 P1 Connect probe to T1 Compatible with any K Type thermocoup...

Page 8: ... CO 02 and Excess Air Scroll or to select FUELTYPE Press Test results and LOG number will display when done Press to print the results This LOG will be stored in REPORTS EXCHANGE in the MENU screen Call for heat on the system Observe and wait for O2 readings to stabilize After the blower turns on press the to start the Post Blower test Combustion Analyzer C165 CO CO 2 T E M P P R S Status L I N K ...

Page 9: ... will be stored in REPORTS ROOM CO in the MENU screen PRINTING AND LOGGING Align Printer in line above analyzer Press or Buttons to select Log number of that type of Report Scroll or to PRINT Rotate rotary dial to Menu Press or Buttons to select Report Press Button to select Report Press Button to print Report Log Number Press or Buttons to view types of Reports Press Button to select Report type ...

Page 10: ...ays dispose batteries using approved disposal methods that protect the environment Remove the probe from the flue and allow analyzer to purge with fresh air until readings return to zero O2 to 20 9 CAUTION probe tip will be HOT POWERING OFF When you power off the C165 there is a 10 second purge CAUTION Make sure you do not exceed the analyzer s operating specifications Do not exceed the flue probe...

Page 11: ...nd misuse For full warranty details please refer to the Owner s Manual on the C165 product page see the link above If a UEi product fails under warranty we will replace it but we need the unit back so we can identify and fix the problem For an RMA call Team UEi 1 800 547 5740 UEi Test Instruments 1 800 547 5740 info ueitest com This warranty gives you specific legal rights You may also have other ...

Page 12: ... hour Service Analyzers received for standard recertification and service through UEi Service are shipped back on the next business day Free Shipping UEi Service offers free shipping both to and from our service center When customers book their recertification they receive a prepaid UPS Ground shipping label Get full details at www ueitest com service BACKED BY Complete care for your C160 series c...

Reviews: