background image

Introduction

The CA383B measures both AC and DC current and is compatible with
most DMMs which have a 200mV and 200mA AC range or a 40mA and
400mA AC range. 

Features include

• 300 Amps AC
• Max. jaw opening 1.2” (30mm)
• Dimensions: 3.1 x 6.1 x 1.4 (89 x 156 x 35mm)
• Output: 1mV AC per 0.1 Amp AC

Operating Instructions

Measuring AC Current

1.  Observing the polarity markings on the CA383B connector, 

plug the test lead into the input jacks on your digital 
multimeter. The 

"-"

on the CA383B connector plugs into 

the 

"COM"

jack and the 

"+"

plugs into the 

"mA/µA"

jack on 

your multimeter.

2.  If your multimeter is equipped with a 20mA and 200A AC range 

use one of the following settings:
a) Set the multimeter on 20mA AC and the CA383B on the 40 

range for measuring 0 to 20A AC.

b) Set the multimeter on 200mA AC and the CA383B on the 

400 range for measuring 0 to 200A AC.

If your multimeter is equipped with a 40mA and 400A AC range 
use one of the following settings:
a) Set the multimeter on 40mA AC and the CA383B on the 40 

range for measuring 0 to 40A AC.

b) Set the multimeter on 400mA AC and the CA383B on the 

400 range for measuring 0 to 400A AC.

3.  Clamp the jaw of the CA383B around a single current 

carrying wire.

NOTE:

Clamp around only one wire at a time. If the CA383B 

is clamped around two or more wires, it will not work properly

4.  Take the reading directly from the digital multimeter's display.

NOTE:

1mV = 1A

Specifications

CA383B-MAN    

P. 1

Measuring Ranges

AC Amps

0-20A on 20mA or
200mV on 200mA AC range
0-40A on 40mA or
400mV on 400mA AC range

Output

AC Amps

1mV AC per 1A AC

Accuracy

40A

±(1.5% of r2
least significant digits)

400A

±(1.5% of r4
least significant digits)

Operating Temperature

+32˚F to 122˚F (0˚C to 50˚C)

Reviews: