background image

Air velocity average for multi points

1.  Turn the meter ON, and position the fan at the first point to be 

measured. As soon as the first measurement is completed, press
the 

HOLD

key (you will hear a single beep) and release it. The

display will show a HOLD indicator above the reading (Fig 4). The
reading is locked at the value display when hold was pressed.

2.  Press the 

MIN/MAX

record key (you will hear a single beep) 

and release it. The display will show a digit numbered from 
1 to 8. This number represents the point that is being recorded
(Fig 5).

Repeat this process until all desired points have been measured 
and recorded.

3.  Once all measurements have been recorded, press the 

NEXT

DIGIT/MULTIPOINT AVERAGE

key. The meter will display

the average air velocity reading and number of points 
measured (Fig 6). The meter can record a total of eight (8) points
at one time.

4.  To CLEAR THE MEMORY of current Multi Point Average readings, 

press and hold the 

NEXT DIGIT/MULTIPOINT AVERAGE

key

until the unit beeps twice, then release. The unit must be in 
velocity/FPM mode to clear current average readings.

Air Flow (CFM) Average for Multipoints

Once the multi-point average is determined:

1.  Press the 

MODE

button once, and confirm the correct free 

area setting is locked into the meter. (If the free area setting must
be adjusted, make necessary changes now).

2.  If the free area setting is correct, press the 

MODE

button again to 

enter the meter's air flow mode. 

3.  Press 

MIN/MAX

record button. The unit will begin to record the 

readings. The instrument displays the average velocity by default.
Each of the 

MIN/MAX

button cycles the display through:

•  Real-time readings
•  MIN velocity
• M AX velocity
•  Back to AVG velocity

Note:

Feet Per Minute (FPM) readings can be converted to 

CFM readings.

4.  Press the 

HOLD

button to store the readings before 

moving the meter away from an air flow source.

5.  Press 

ON/OFF RESET

twice to clear the current MIN/MAX

average readings and once to turn the meter OFF.

Direct measuring of air flow (Single Point) CFM

Air velocity measurement is calculated by multiplying the air velocity
readings times the free area dimension. Free area is publishing by the
grill and register manufacturer you are servicing.

Determine the free area of the air source you are measuring and enter
it into the meter.

1. Turn the power ON.

2.  Press the mode select once (you will hear one beep). The meter 

will display 

AREA

in upper case letters at the top of the display,

and 

1.111

, with a flashing initial digit (Fig 3). This is the free area

default setting.

3.  To increase numbers, the flashing digit can be changed by 

pressing the 

HOLD/ADVANCE

key.

4.  To change the value of other digits, press the 

NEXT DIGIT

key.

5.  Press the 

RECORD

key. The flashing will stop. Then press 

the HOLD key to save the changed value. The meter returns to
FLOW mode automatically.

6.  Press the 

MODE

select button once to return to the "vel" mode.

The meter is now ready to measure air flow (CFM).

MIN/MAX/AVG CFM READING

Repeat steps 1-6 from earlier instructions to obtain MIN/MAX/AVG CFM
readings from a single point.

(Fig 3)

(Fig 4)

(Fig 5)

(Fig 6)

DAFM2-MAN    

P. 2

Summary of Contents for DAFM2

Page 1: ...1 800 547 5740 Fax 503 643 6322 www ueiautomotive com email info ueiautomotive com DAFM2 INSTRUCTION MANUAL ...

Page 2: ...e this instrument WARNING Objects striking the fan may damage meter Controls and Indicators 1 ON OFF RESET 2 MODE Select VEL FPM FREE AREA FLOW CFM 3 HOLD ADVANCE 4 MIN MAX RECORD Single Print 5 NEXT DIGIT Multi point Average Operating Instructions Measuring Air Velocity Single Point feet per minute FPM 1 Press the ON OFF button to turn the meter on Every display feature will appear for a few seco...

Page 3: ...s MIN MAX record button The unit will begin to record the readings The instrument displays the average velocity by default Each of the MIN MAX button cycles the display through Real time readings MIN velocity MAX velocity Back to AVG velocity Note Feet Per Minute FPM readings can be converted to CFM readings 4 Press the HOLD button to store the readings before moving the meter away from an air flo...

Page 4: ... the same time then release ON only An n will appear on the LCD You can then release the HOLD key The meter will remain ON until the meter is turned off Changing default settings 1 The default setting for the air velocity measuring unit is feet minute The default setting for the unit of temperature is F To change the measuring units to meters sec and C a Turn the meter ON by pressing the ON and AV...

Page 5: ...mplied warranties of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required before warranty...