INSTRUCTION MANUAL

ENGLISH

DL200

CATIII Clamp Meter and 

Voltage Tester

WARRANTY 

The DL200 is warranted to be free from defects in materials and workmanship 

for a period of two years from the date of purchase. If within the warranty 

period your instrument should become inoperative from such defects, the unit 

will be repaired or replaced at UEi’s option. This warranty covers normal use 

and does not cover damage which occurs in shipment or failure which results 

from alteration, tampering, accident, misuse, abuse, neglect or improper 

maintenance. Batteries and consequential damage resulting from failed 

batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of 

merchantability and fitness for a particular purpose, are limited to the express 

warranty. UEi shall not be liable for loss of use of the instrument or other 

incidental or consequential damages, expenses, or economic loss, or for any 

claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required 

before warranty repairs will be rendered. Instruments out of warranty will be 

repaired (when repairable) for a service charge

This warranty gives you specific legal rights. You may also have other rights, 

which vary from state to state.

DISPOSAL

 CAUTION:

  

This symbol indicates that equipment and its accessories 

shall be subject to separate collection and correct disposal.

CLEANING

Periodically clean your meter’s case using a damp cloth. DO NOT use abrasive, 

flammable liquids, cleaning solvents, or strong detergents as they may damage the 

finish, impair safety, or affect the reliability of the structural components.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of time. 

Do not expose to high temperatures or humidity. After a period of storage in extreme 

conditions exceeding the limits mentioned in the General Specifications section, allow 

the instrument to return to normal operating conditions before using it.

Copyright © 2016 UEi. All Rights Reserved.

600V

CAT III

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Summary of Contents for DL200

Page 1: ...such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge This warranty gives you specific legal rights You may also have other rights which vary from state to state DISPOSAL CAUTION This symbol indicates that equipment ...

Page 2: ...he leads behind the finger guards molded into the probe Use caution when working with voltages above 60V DC or 25V AC RMS Such voltages pose shock hazards To avoid false readings that can lead to electrical shock replace batteries if a low battery indicator appears Unless measuring voltage or current shut off and lockout power before measuring resistance or capacitance Always adhere to national an...

Page 3: ...g the clamp lever be careful not to inadvertently press any button when gripping the meter That will place the meter in a mode that was not desired F Hold Button Press once to enable Hold Press again to return to live readings Captures present value Press and hold the Hold button when meter is in Hold mode to disable Auto power off mode Press and hold again to enable Auto power off mode When power...

Page 4: ... Volts Ranges Resolution Accuracy Overload Protection 1V to 199 9V 0 1V 1 5 5 dgts 600V 200V to 600V 1V DC Volts Ranges Resolution Accuracy Overload Protection 1V to 19 9V 0 01V 1 5 3 dgts 600V 20V to 199 9V 0 1V 200V to 600V 1V Minimum measurement AC mV 500mV DC mV 40mV Response time input AC 100V 1 sec Max displayed value 660V AC DC High warning symbol input voltage AC30V DC30V Meter beeps input...

Page 5: ...re than 200A AC Features HOLD AC Amps Jaw Input Ranges Resolution Accuracy Overload Protection 1A to 200A 0 1A 2 0 5 dgts 600V Frequency Range sine wave 45Hz to 400Hz Maximum Displayed value AC220A Minimum Displayed value AC 500mA CAT III 600V VΩ DL200 600V CAT III 200A HOLD Test Lead Notes CATIV 600V Measurement Locations The DL200 is CATIII rated to IEC 61010 1 3rd edition standards Do not attem...

Page 6: ...are aligned with arrows Remove battery cover Replace the old batteries with 2 new AAA batteries Replace the battery cover Rotate latches until the lock symbols are aligned with arrows S N CATIII 600V OPEN LOCK OPEN LOCK CATIII 600V OPEN LOCK OPEN LOCK Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Reviews: