Continuity

• Buzzer sounds at less than 40Ω.

 WARNING

• Do not measure resistance on a live circuit.

Features:    

HOLD

Continuity

Audible threshold

Response time

Overload Protection

Approx : < 40Ω

50ms

600V

CAT III

600V

DL200

600V         CAT III     200A

HOLD

Single

Conductor

Only

AC Amps: <200A

CAT III

600V

DL200

600V         CAT III     200A

• Center wire in conductor alignment marks for best accuracy.
• Opposing currents cancel 

(use line-splitter when necessary).

 WARNING

• Keep hands below guard when measuring high current levels.
• Do not attempt to measure more than 200A AC.

Features:    

HOLD

AC Amps – Jaw Input

Ranges

Resolution

Accuracy

Overload Protection

1A to 200A

0.1A

±(2.0% + 5 dgts)

600V

Frequency Range: sine wave: 45Hz to 400Hz

Maximum Displayed value: AC220A

Minimum Displayed value: AC 500mA

CAT III

600V

DL200

600V         CAT III     200A

HOLD

Test Lead Notes

CATIV 600V Measurement Locations

• The DL200 is CATIII rated to IEC 61010-1 3rd edition standards. Do not 

attempt to measure in locations that requires a CATIV rated meter. Remove 
the CATIV test lead caps and use the CATIII 1000V test lead measurement 
locations.

CATIII 1000V Measurement Locations

• CATIV shields must be removed for CATII and CATIII locations. 

4mm

18mm

4mm

CATIV

600V

CATIV

600V

CATIII

1000V

18mm

•  Default   =
•  Press x1 =
•  Press x2 =

Summary of Contents for DL200

Page 1: ...such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge This warranty gives you specific legal rights You may also have other rights which vary from state to state DISPOSAL CAUTION This symbol indicates that equipment ...

Page 2: ...he leads behind the finger guards molded into the probe Use caution when working with voltages above 60V DC or 25V AC RMS Such voltages pose shock hazards To avoid false readings that can lead to electrical shock replace batteries if a low battery indicator appears Unless measuring voltage or current shut off and lockout power before measuring resistance or capacitance Always adhere to national an...

Page 3: ...g the clamp lever be careful not to inadvertently press any button when gripping the meter That will place the meter in a mode that was not desired F Hold Button Press once to enable Hold Press again to return to live readings Captures present value Press and hold the Hold button when meter is in Hold mode to disable Auto power off mode Press and hold again to enable Auto power off mode When power...

Page 4: ... Volts Ranges Resolution Accuracy Overload Protection 1V to 199 9V 0 1V 1 5 5 dgts 600V 200V to 600V 1V DC Volts Ranges Resolution Accuracy Overload Protection 1V to 19 9V 0 01V 1 5 3 dgts 600V 20V to 199 9V 0 1V 200V to 600V 1V Minimum measurement AC mV 500mV DC mV 40mV Response time input AC 100V 1 sec Max displayed value 660V AC DC High warning symbol input voltage AC30V DC30V Meter beeps input...

Page 5: ...re than 200A AC Features HOLD AC Amps Jaw Input Ranges Resolution Accuracy Overload Protection 1A to 200A 0 1A 2 0 5 dgts 600V Frequency Range sine wave 45Hz to 400Hz Maximum Displayed value AC220A Minimum Displayed value AC 500mA CAT III 600V VΩ DL200 600V CAT III 200A HOLD Test Lead Notes CATIV 600V Measurement Locations The DL200 is CATIII rated to IEC 61010 1 3rd edition standards Do not attem...

Page 6: ...are aligned with arrows Remove battery cover Replace the old batteries with 2 new AAA batteries Replace the battery cover Rotate latches until the lock symbols are aligned with arrows S N CATIII 600V OPEN LOCK OPEN LOCK CATIII 600V OPEN LOCK OPEN LOCK Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Reviews: