INSTRUCTION MANUAL

ENGLISH

DL220

CATIV Clamp Meter and   

Voltage Tester

WARRANTY 

The DL220 is warranted to be free from defects in materials and workmanship 

for a period of two years from the date of purchase. If within the warranty 

period your instrument should become inoperative from such defects, the unit 

will be repaired or replaced at UEi’s option. This warranty covers normal use 

and does not cover damage which occurs in shipment or failure which results 

from alteration, tampering, accident, misuse, abuse, neglect or improper 

maintenance. Batteries and consequential damage resulting from failed 

batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of 

merchantability and fitness for a particular purpose, are limited to the express 

warranty. UEi shall not be liable for loss of use of the instrument or other 

incidental or consequential damages, expenses, or economic loss, or for any 

claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required 

before warranty repairs will be rendered. Instruments out of warranty will be 

repaired (when repairable) for a service charge.
For more information on warranty and service, contact: 

This warranty gives you specific legal rights. You may also have other rights, 

which vary from state to state.

DISPOSAL

 CAUTION:

  

This symbol indicates that equipment and its accessories 

shall be subject to separate collection and correct disposal.

CLEANING

Periodically clean your meter’s case using a damp cloth. DO NOT use abrasive, 

flammable liquids, cleaning solvents, or strong detergents as they may damage the 

finish, impair safety, or affect the reliability of the structural components.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of time. 

Do not expose to high temperatures or humidity. After a period of storage in extreme 

conditions exceeding the limits mentioned in the General Specifications section, allow 

the instrument to return to normal operating conditions before using it.

Copyright © 2016 UEi. All Rights Reserved.

600V

CAT IV

CAT IV

600V

DL220

600V         CAT IV     200A

CA

T IV

600V

CA

T IV

600V

www.

.com

information@itm.com

1.800.561.8187

Summary of Contents for DL220

Page 1: ...eipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge For more information on warranty and service contact This warranty gives you specific legal rights You may also have other rights which vary from state to state DISPOSAL CAUTION This symbol indicates that equipment...

Page 2: ... the finger guards molded into the probe Use caution when working with voltages above 60V DC or 25V AC RMS Such voltages pose shock hazards To avoid false readings that can lead to electrical shock replace batteries if a low battery indicator appears Unless measuring voltage or current shut off and lockout power before measuring resistance or capacitance Always adhere to national and local safety ...

Page 3: ...e the meter displays the new value Press and hold the A Hold button when meter is in Auto Hold mode to disable Auto power off mode Press and hold again to enable Auto power off mode When the meter is in Auto Hold mode there will be an audible beep while the meter captures a new stable value LRA Inrush Press and hold to enable LRA Inrush mode Press and hold to return to live readings Used for measu...

Page 4: ...D LRA INRUSH AC DC Voltage 600V AC DC WARNING Do not attempt to measure more than 600V AC DC Keep hands below line when measuring high current levels Do not exceed 600V DC or AC RMS on either the common or multifunction test leads as measured from earth ground Select AC or DC Voltage Features A HOLD LRA INRUSH AC Volts Ranges Resolution Accuracy Overload Protection 1V to 199 9V 0 1V 1 5 5 dgts 600...

Page 5: ...Frequency Range sine wave 45Hz to 400Hz Maximum Displayed value AC220A Minimum Displayed value AC 500mA CAT IV 600V VΩ DL220 CAT IV 600V VΩ DL220 A HOLD LRA INRUSH Single Conductor Only LRA Inrush The meter must be in AC Amps mode first to be placed into LRA measurement mode The UEi LRA Inrush is programmed to properly capture the starting current for compressor motors Press and hold A Hold LRA In...

Page 6: ...V C A T I V 6 0 0 V OPEN LOCK OPEN LOCK OPEN LOCK OPEN LOCK Test Lead Notes CatIV 600V Measurement Locations Ensure the test lead shield is pressed firmly in place Failure to use the CATIV shield increases arc flash risk CATII 1000V Measurement Locations CATIV shields may be removed for CATII locations This will allow testing on recessed conductors such as standard wall outlets Take care not to lo...

Reviews: