Continuity

•  Buzzer sounds at less than 40Ω.

 WARNING

•  Do not measure resistance on a live circuit.

Features:    

A-HOLD

LRA INRUSH

Continuity

Audible threshold

Response time

Overload Protection

Approx : < 40Ω

50ms

600V

CAT IV

600V

DL220

A-HOLD

LRA INRUSH

AC Amps: <200A

•  Center wire in conductor alignment marks for best accuracy.
•  Opposing currents cancel 

(use line-splitter when necessary).

 WARNING

•  Keep hands below guard when measuring high current levels.
•  Do not attempt to measure more than 200A AC.

Features:    

A-HOLD

LRA INRUSH

AC Amps

Ranges

Resolution

Accuracy

Overload Protection

1A to 200A

0.1A

±(2.0% + 5 dgts)

600V

Frequency Range: sine wave: 45Hz to 400Hz

Maximum Displayed value: AC220A

Minimum Displayed value: AC 500mA

CAT IV

600V

DL220

CAT IV

600V

DL220

A-HOLD

LRA INRUSH

Single

Conductor

Only

LRA Inrush

•  The meter must be in AC Amps mode first to be placed into LRA  

measurement mode.

•  The UEi LRA Inrush is programmed to properly capture the starting current   

for compressor motors.

•  Press and hold 

A-Hold/LRA Inrush

 button – INRUSH will now be shown on 

the display.

•  Activate compressor and read value on display.
•  Press and hold 

A-Hold/LRA Inrush

 button to return to live readings.

•  Press x1 = 

A-HOLD

•  Press again to power    

  off A-Hold
•  Press and hold =  
 

LRA INRUSH

•   Press and hold again   

  to power off LRA Inrush

A-HOLD

LRA INRUSH

CAT IV

600V

DL220

CAT IV

600V

DL220

A-HOLD

LRA INRUSH

Single

Conductor

Only

www.

.com

information@itm.com

1.800.561.8187

Summary of Contents for DL220

Page 1: ...eipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge For more information on warranty and service contact This warranty gives you specific legal rights You may also have other rights which vary from state to state DISPOSAL CAUTION This symbol indicates that equipment...

Page 2: ... the finger guards molded into the probe Use caution when working with voltages above 60V DC or 25V AC RMS Such voltages pose shock hazards To avoid false readings that can lead to electrical shock replace batteries if a low battery indicator appears Unless measuring voltage or current shut off and lockout power before measuring resistance or capacitance Always adhere to national and local safety ...

Page 3: ...e the meter displays the new value Press and hold the A Hold button when meter is in Auto Hold mode to disable Auto power off mode Press and hold again to enable Auto power off mode When the meter is in Auto Hold mode there will be an audible beep while the meter captures a new stable value LRA Inrush Press and hold to enable LRA Inrush mode Press and hold to return to live readings Used for measu...

Page 4: ...D LRA INRUSH AC DC Voltage 600V AC DC WARNING Do not attempt to measure more than 600V AC DC Keep hands below line when measuring high current levels Do not exceed 600V DC or AC RMS on either the common or multifunction test leads as measured from earth ground Select AC or DC Voltage Features A HOLD LRA INRUSH AC Volts Ranges Resolution Accuracy Overload Protection 1V to 199 9V 0 1V 1 5 5 dgts 600...

Page 5: ...Frequency Range sine wave 45Hz to 400Hz Maximum Displayed value AC220A Minimum Displayed value AC 500mA CAT IV 600V VΩ DL220 CAT IV 600V VΩ DL220 A HOLD LRA INRUSH Single Conductor Only LRA Inrush The meter must be in AC Amps mode first to be placed into LRA measurement mode The UEi LRA Inrush is programmed to properly capture the starting current for compressor motors Press and hold A Hold LRA In...

Page 6: ...V C A T I V 6 0 0 V OPEN LOCK OPEN LOCK OPEN LOCK OPEN LOCK Test Lead Notes CatIV 600V Measurement Locations Ensure the test lead shield is pressed firmly in place Failure to use the CATIV shield increases arc flash risk CATII 1000V Measurement Locations CATIV shields may be removed for CATII locations This will allow testing on recessed conductors such as standard wall outlets Take care not to lo...

Reviews: