background image

DL419

FUNCTIONS

  AC/DC Voltage

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

  AC/DC Current

 

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

  AC/DC MicroAmps

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

  Audible continuity

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 Resistance

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  Diode test

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 Capacitance

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FEATURES

  True RMS

  LRA Inrush current measurement

  Data hold mode

 

HOLD

  MIN/MAX (All ranges except Capacitance)

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

Min/Max

  Rel/DC A Zero mode

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

Rel/Zero

  Back-lit display  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

  Non-contact voltage detect   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .

NCV

  Magnetic mount

  Autoranging measurements with manual ranging capability

  Bar Graph

  a.   The bar graph shows an approximate analog representation of a    

  measurement.
  b.   The bar graph responds much faster than the digital display.
  c.   The scale of the bar graph is zero to the maximum reading of  

    the selected range.

 

 Auto-Power-Off:

 After 30 minutes of non-use 

  Low battery:

 

 is displayed if battery voltage drops below  

 

    operating voltage.  

GENERAL SPECIFICATIONS

 Altitude: 

Operating - up to 2000m (6,561 ft.)

 

 

Storage - 10,000m (32,808 ft.)

 Humidity:

 80% max 

  Operating Temperature:

 32°F to 104°F (0°C to 40°C) at < 75% R.H

  Storage Temperature:

 -4°F to 140°F (-20°C to 60°C) at < 80% R.H

  Relative humidity:

 0% to 80% at 32°F to 95°F (0°C to 35°C),

   

 

0% to 70% at 32°F to 131°F (0°C to 55°C)

  Temperature Coefficient:

 Nominal 0.1 x (Specified accuracy) / °C

 

 

(<18°C or >28°C ; <64°F or >82°F) 

  Pollution degree:

 2

 Display:

 3-3/4 digits 4000 counts single LCD display with 20 segments    

   

bar graph 

  Refresh Rate:

 3 times/sec 

 

 Overrange:

 "OL" is displayed 

 

 Polarity:

  Automatic(no indication for positive polarity) ; Minus(-) sign   

   

for negative polarity   

 Dimensions:

 10.6" x2.5" x 1.5"

 Weight:

 16.8oz.

 Calibration:

 Accurate for one year

  CAT Rating:

 CAT IV 600V, CAT III 1000V

 Certifications:

 ETL & C-ETL Listed IEC61010-2-032

  Battery type:

 2 x 1.5V AAA or LR03

 

  Silicon Test Lead: 

IEC61010-2-031

 

 Accuracy:

 ± (% of r # of least significant digits)

 WARNINGS 

To ensure safe operation and service of the tester, follow these instructions. 

Failure to observe these warnings can result in severe injury or death.

 

Before each use, verify meter operation by measuring a known voltage or  

 current. 

 

Never use the meter on a circuit with voltages that exceed the category  

  based rating of this meter.

 

Do not use the meter during electrical storms, or in wet weather.

 

Do not use the meter or test leads if they appear to be damaged.

 

Ensure meter leads are fully seated, and keep fingers away from the metal  

  probe contacts when making measurements.

 

Do not open the meter to replace batteries while the probes are connected.

 

Use caution when working with voltages above 60V DC, or 25V AC RMS. 

 

 

Such voltages pose a shock hazard.

 

To avoid false readings that can lead to electrical shock, replace batteries  

  if a low battery indicator appears.

 

Unless measuring voltage or current, shut off and lock out power before  

  measuring resistance or capacitance.

 

Always adhere to local and national safety codes. Use Personal Protective  

  Equipment (PPE) to prevent shock and arc blast injury.

SYMBOLS USED ON LCD

~

AC Measurement

DC Measurement

Negative DC Value

AT

Auto Range Active

O.L.

Overload: Range Exceeded

Apo

Auto Power-Off Active

Low Battery

HOLD

Hold Active

MIN

Minimum Reading

MAX

Maximum Reading

Relative / Zero Mode

A

Current in Amps

V

Voltage Measurement

Diode Test

Ω

Resistance in Ohms

k

Kilo ( x 10

3

)

µ

A

MicroAmps

M

Mega ( x 10

)

m

Milli ( x 10

-3 

)

nF/µF

Nanofarad/Microfarad

 

INTERNATIONAL SYMBOLS

~

AC Alternating Current

Warning or Caution

DC Direct Current

Dangerous levels

DC/AC Voltage or Current

Double Insulated Class II

Ground

Safe for disconnect  

from live conductors

AC Source

True RMS Digital Clamp-On 

Multimeter

PLEASE

RECYCLE

10093  01/15

WARRANTY

The DL419 is warranted to be free from defects in materials and workmanship 

for a period of two year from the date of purchase . If within the warranty 

period your instrument should become inoperative from such defects, the unit 

will be repaired or replaced at UEi’s option . This warranty covers normal use 

and does not cover damage which occurs in shipment or failure which results 

from alteration, tampering, accident, misuse, abuse, neglect or improper 

maintenance . Batteries and consequential damage resulting from failed 

batteries are not covered by warranty . 

Any implied warranties, including but not limited to implied warranties of 

merchantability and fitness for a particular purpose, are limited to the express 

warranty . UEi shall not be liable for loss of use of the instrument or other 

incidental or consequential damages, expenses, or economic loss, or for any 

claim or claims for such damage, expenses or economic loss . 

A purchase receipt or other proof of original purchase date will be required 

before warranty repairs will be rendered . Instruments out of warranty will be 

repaired (when repairable) for a service charge . 

BATTERY REPLACEMENT

•  When 

 indicator is displayed on the LCD, batteries must be replaced .

• Remove the back screw and replace 2 x AAA batteries .

CLEANING

Turn instrument off and disconnect test leads . Clean the instrument by using  

a damp cloth . Do not use abrasive cleaners or solvents .

STORAGE

Remove the batteries when instrument is not in use for a prolonged period 

of time . Do not expose to high temperatures or humidity . After a period 

of storage in extreme conditions exceeding the limits mentioned in the 

Specifications section, allow the instrument to return to normal operating 

conditions before using it .

DISPOSAL / RECYCLE

Caution:

 This symbol indicates that equipment and its 

accessories shall be subject to a separate collection and correct 

disposal .

Copyright © 2015 UEi . All Rights Reserved

CAT III      1000V

CAT IV     600V

DL419

True RMS

600V                     1000A

CAT IV

NCV

MAX/

MIN

LRA Inrush

Zero

DC/

Rel

RANGE

INRUSH

VO

LTA

G

E

DET

EC

TO

R

 μA

 A

V

MFD

INSTRUCTION MANUAL

ENGLISH

NAVIGATION

•  Press briefly to turn the meter on
•  Press and hold “HOLD” while turning on 
     to disable auto power off .
•  Press and hold to turn the meter off
•  Default is AC Volts

The new user interface allows direct access from any mode .

•  Press to select DC µA measurement mode . 
•  Press a second time for AC µA . 

•  Press to select AC Amps . 
•  Press a second time for DC Amps . 

MF

D

•  Press to select continuity . 
•  Press a second time for resistance . 
•  Press a third time for capacitance and a fourth time for diode . 

V

•  Press to select AC Volts . 
•  Press again to select DC Volts . 

NCV

•  Non-Contact Voltage Detection key is used to detect power with a 

sensor located at the tip of the clamp head and indicates positive 

response with an audible alarm and visual LED indicator light just 

above the “NCV” button . 

•  Do not use non-contact voltage detector to determine if there 

is current in the wire . Detection operation could be affected by 

socket design, insulation thickness, type and other factors . 

•  Voltage indicator light may also light when voltage is present on 

the meter’s input jack or from external interference sources such 

as motors, flashlights etc . 

MAX/

MIN

•  Press to enter Max / Min mode; the largest and smallest values 

will be saved while in this mode .

•  Press repeatedly to alternate between the maximum and 

minimum readings .

•  Press for 2 seconds to return to live reading and clear the stored 

maximum and minimum values .

Note

Select range prior to selecting Min/Max to capture large 

values

RANGE

•  Press repeatedly to cycle through manual ranges .
•  Press for 2 seconds to return to auto ranging mode .
•  AT is displayed on LCD only during auto ranging mode .

    Note:

 

Select range prior to Min/Max for best results.

       

                               

x1

x1

Zero

DC/

Rel

•  Press to zero any offset in Volts AC/DC, DC µA, Amps AC/DC .  
     ◊ Used to monitor change from the present displayed value
•  Required during DC Amp measurement to establish a zero level

 

 

DO NOT use Zero DC/Rel mode at voltages greater than 

1000V . 

 

HOLD

•  Press to hold the reading on the display . Press again to return to 

live reading .

•  Press and hold "work light" key for 2 seconds to turn on . Press and 

hold again to turn off .

CAT III      1000V

CAT IV     600V

DL419

True RMS

600V                     1000A

CAT IV

NCV

MAX/

MIN

LRA Inrush

Zero

DC/

Rel

RANGE

INRUSH

VO

LTA

G

E

DET

EC

TO

R

 μA

 A

V

MFD

CAT III      1000V

CAT IV     600V

DL419

True RMS

600V                     1000A

CAT IV

NCV

MAX/

MIN

LRA Inrush

Zero

DC/

Rel

RANGE

INRUSH

VO

LTA

G

E

DET

EC

TO

R

 μA

 A

V

MFD

HOLD

www.

.com

information@itm.com

1.800.561.8187

All manuals and user guides at all-guides.com

all-guides.com