background image

DL469

NCV

CAT III 1000V

MAX

µA

A

 CAT Ill

1000V                      400A

True RMS

INSTRUCTION MANUAL

ENGLISH

DL469

1-800-547-5740

www.ueitest.com • email: info@ueitest.com

AC 400A TRMS Clamp Meter

WARRANTY 

The DL469 is warranted to be free from defects in materials and workmanship 

for a period of two years from the date of purchase. If within the warranty 

period your instrument should become inoperative from such defects, the unit 

will be repaired or replaced at UEi’s option. This warranty covers normal use 

and does not cover damage which occurs in shipment or failure which results 

from alteration, tampering, accident, misuse, abuse, neglect or improper 

maintenance. Batteries and consequential damage resulting from failed 

batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of 

merchantability and fitness for a particular purpose, are limited to the express 

warranty. UEi shall not be liable for loss of use of the instrument or other 

incidental or consequential damages, expenses, or economic loss, or for any 

claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required 

before warranty repairs will be rendered. Instruments out of warranty will be 

repaired (when repairable) for a service charge
For more information on warranty and service, contact: 

www.ueitest.com • Email: info@ueitest.com

1-800-547-5740

This warranty gives you specific legal rights. You may also have other rights, 

which vary from state to state.

DISPOSAL

 CAUTION:

  

This symbol indicates that equipment and its accessories 

shall be subject to separate collection and correct disposal.

CLEANING

Periodically clean your meter’s case using a damp cloth. DO NOT use abrasive, 

flammable liquids, cleaning solvents, or strong detergents as they may damage the 

finish, impair safety, or affect the reliability of the structural components.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of time. 

Do not expose to high temperatures or humidity. After a period of storage in extreme 

conditions exceeding the limits mentioned in the General Specifications section, allow 

the instrument to return to normal operating conditions before using it.

Copyright © 2016 UEi. All Rights Reserved.

1000V

CAT III

Summary of Contents for DL469

Page 1: ...any claim or claims for such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge For more information on warranty and service contact www ueitest com Email info ueitest com 1 800 547 5740 This warranty gives you specifi...

Page 2: ...robe contact when making measurements Always grip the leads behind the finger guards molded into the probe Do not open the meter to replace batteries while the probes are connected Use caution when working with voltages above 60V DC or 25V AC RMS Such voltages pose shock hazards To avoid false readings that can lead to electrical shock replace batteries if a low battery indicator appears Unless me...

Page 3: ...AT Rating for Clamp jaw G Hand Guide Used as a point of reference for the operator s safety H NCV Alert Light Indicates voltage when in NCV mode I Clamp Lever Opens and closes current clamp jaw Do not allow fingers or objects to become pinched in the base as the jaw closes J Hold Button Press to hold the reading on the display Press again to return to live reading Press and hold to turn on Worklig...

Page 4: ... Square 0 5 error at 0 1kHz max Triangle 0 5 error at 1 2kHz max Range Resolution Accuracy Overload Protection 400Ω 0 1Ω 1 0 5 dgts 600V RMS 4kΩ 1Ω 40kΩ 10Ω 400kΩ 100Ω 4MΩ 0 001MΩ 40MΩ 0 01MΩ 1 5 5 dgts Resistance 40MΩ Features HOLD WARNING Do not measure resistance on a live circuit DL469 NCV CAT III 1000V MAX µA A CAT Ill 1000V 400A True RMS M Default Press x1 Test Lead Notes Cat IV and CAT III ...

Page 5: ...idth 400Hz to 4kHz 15 to 85 Single Conductor Only DL469 NCV CAT III 1000V MAX µA A CAT Ill 1000V 400A True RMS Reverse Bias Displays OL DL469 NCV CAT III 1000V MAX µA A CAT Ill 1000V 400A True RMS Forward voltage drop if forward biased O L if reverse biased Features HOLD BAD DIODE 0 Both directions Shorted or Range Open Circuit V Test Current Overload Protection 4 0V 3 0V DC 1 30mA 600V RMS Buzzer...

Page 6: ...ce the battery cover Rotate latches until the lock symbols are aligned with arrows OPEN LOCK OPEN LOCK Select NCV and move the tip of the clamp meter near the voltage source Both an Audible and Visual alert will indicate voltage Non Contact Voltage Detection is used to detect power with the sensor located at the tip of the clamp head Do not use non contact voltage detector to determine if there is...