DRS220 User’s Guide  

 

 

Keypad 

 

 

 

Press for power-on, press/hold for power off. 

 

Press to cycle through displayed units. 

 

Press to select low, medium, or high display resolution. 

 

Press to “zero-out” current reading on display. 

 

Use to adjust various settings and programming values. 

 

For faster adjustments. Used in conjunction with 

 and 

 

“Freezes” display. 

 

Starts programming mode 

 

Activates/Deactivates stored program. 

 

 

DRS220 User’s Guide 

Quick Start 

To operate the DRS220 as a basic weigh scale, perform the following steps: 

Setup 

1.  Unpack the scale as described in the “Unpacking the DRS220” section below. 

2.  Install the batteries into the control box as described in the “Battery Installation” 

section below. 

3.  Place the Weighing Platform on a firm, level surface. 

4.  Turn the DRS220 on by pressing 

5.  Select the proper measurement units by repeated pressing 

. The units will 

cycle as follows: 

kilograms 

è

 pounds 

è

 pounds and ounces 

è

 ounces 

6.  Select the desired display resolution by repeatedly pressing 

 as described in 

the RESOLUTION section. 

Basic Weighing Operation 

1.  If using a container to hold the objects being measured, place it empty on the 

center of the platform. 

2.  Press 

 to “zero-out” the scale. The display will read zero. 

3.  Place the material to measure in the container or on the center of the platform. 

4.  Read the weight on the display. 

5.  A positive number indicates the applied weight is greater than the zero value.  A 

negative number indicates the applied weight is less than the zero value. 

6.  Repeat steps 1 through 5 as necessary. 

7.  Turn the DRS220 off by pressing and holding 

 down until the scale turns off. 

8.  To conserve battery life, the DRS220 will turn itself off after 30 minutes of 

inactivity, unless it is currently running a program (see Programming section).  
The last state of the DRS220 will be restored upon power-up. 

Summary of Contents for DRS220

Page 1: ...ies of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages e...

Page 2: ...erant charging for A C systems Features Large high visibility LCD display Measures Weight in kgs and lbs Built in memory remembers all previous settings Refrigerant Tank Capacity Indicator Rugged Comp...

Page 3: ...y B Alternate Numeric Display C Tank Capacity Percent Indication D Units Indicators E Sound Mute Indicator F Floating Negative Indicator Indicates weight removed from platform G Battery Level Indicato...

Page 4: ...ment units by repeated pressing The units will cycle as follows kilograms pounds pounds and ounces ounces 6 Select the desired display resolution by repeatedly pressing as described in the RESOLUTION...

Page 5: ...ld set of batteries 3 Insert 4 AAA Replace battery cover by aligning tabs and snapping back into place IMPORTANT TO PREVENT DAMAGE TO THE DRS220 CAREFULLY OBSERVE BATTERY POLARITY AS MARKED INSIDE THE...

Page 6: ...display DRS220 User s Guide 9 4 Press and or hold the or keys to set the desired alarm set point To change the set point faster press This will activate the FAST SET mode which will change the set poi...

Page 7: ...on absolute not relative weights DRS220 User s Guide 11 Turning Tank Capacity Mode Off Perform the following steps to turn the Tank Capacity Mode Off 1 While holding down press The SET TANK indicator...

Page 8: ...pply the calibration weight to the platform A number representing the applied reference weight will appear on the display Allow at least 10 seconds for this number to stabilize 8 Press The DRS220 is n...

Page 9: ...hose Open the cylinder valve and purge air from the hose 5 Program the desired refrigerant charge weight as described in the Programming section Activate the program by pressing 6 Open the manifold v...

Page 10: ...DRS220 User s Guide 16 Notes DRS220 User s Guide 17 Notes...

Reviews: