211
Payload (kg)
≤5 kg
Noise Level (30cm away)
< 60 dB
Communication Mode
Digital IO
State Indicator
Power, Working State
Feedback
Air Pressure (Low or Normal)
Notes:
1. The ambient temperature of 850 is 0-50 °C, please reduce the temperature if continuous
high-speed operation is needed.
1.2 850 Specifications
Joint Range
1,4,6
±360°
2
-118°~120°
3
-225°~11°
5
-97°~180°
Payload
5 kg
Degrees of Freedom
6
Repeatability
±0.02 mm
Weight(robotic arm only)
20 kg
Joint Rotating Direction and Joints
Robot Zero Attitude
Summary of Contents for 850
Page 1: ...1...
Page 72: ...72 4 The control box PC and network switch are connected by Ethernet ca ble...
Page 74: ...74 Step3 Open the Properties Step4 Open the IPV4...
Page 89: ...89 Cancel Cancel the selection Save Save the modified data Discard Discard the modified data...
Page 145: ...145 1 6 6 GPIO Control Box and End tool interface...
Page 149: ...149 1 6 7 End Effector...
Page 197: ...197 State 6 Stop Generally use studio will generate state 6 and state 6 is also a kind of stop...