3
UFO LIGHTING
INSTALLATION
CONNECTIONS
There are 3 connections required – the fibre port, the mains supply cable and, optionally, the
DMX control cable. The fibre port should be connected first. Connect and secure the fibre optic
connector into the 30mm diameter collar and secure using the M5 locking screw.
Connect the IEC power cord into the desktop PSU and plug the mains plug into the electrical
supply socket. Switch on power. The LED Indicator will illuminate and the light source is ready
for use.
If no light is produced consult the troubleshooting section.
As well as the standard XLR connectors for DMX connection, the Cube is also fitted with RJ45
connectors which also offer DMX capability. Details of these are below:
Pin No:
1
2
3
4
5
6
7
8
Colour
White
Orange Orange
White
Green
Blue
White
Blue
Green
White
Brown
Brown
Function DMX+
DMX-
Spare
Spare
Spare
Spare
Ground Ground
XLR =
Pin 3
Pin 2
-
-
-
-
Pin 1
Pin 1
Note:
It is recommended that a 120ohm terminating resistor be
connected across DMX+ and DMX- on the last light source
on the DMX universe or cable run
If DMX control is required, connect up
the DMX control cables to the XLR
sockets on the rear of the light
source. The pin out details for the
plugs are shown right.