background image

INSTALLATION

13

UFO

 

LIGHTING

CONNECTION

 - 

FOR

 

REMOTE

 

DC

 

OPERATION

 

(

DC

 

SUFFIX

 

MODELS

)

There may up to three connections required to be connected via the appropriate gland: 
 
1. The fibre harness. 
2. The DMX or 0-10V cables for any light sources with that control functionality 
3.  DC supply cable to the enclosure.  
 
The fibre harness should be connected first. Loosen the fibre optic gland in the gland 
plate and carefully feed the harness through the gland, insert the common end connector 
into the light source aperture and tighten the locking screw to hold it in place.  Ensure 
the fibre optic connector is fully inserted into the aperture before tightening the gland to 
create a seal. Do not overtighten the nylon gland. Never run the luminaire with the fibre 
optic harness out of the aperture.  
 
Loosen the gland for the DMX or 0-10V cables and feed the cables carefully through the 
gland leaving sufficient slack inside the enclosure to reach the back of the light source. 
Tighten the gland and fit RJ45 or XLR  connectors to the cables as detailed in the light 
source user guide. Plug the cables into the light source. 
 
Loosen the gland for the DC cable and feed the cable carefully through the gland leaving 
sufficient slack inside the enclosure to reach the terminal block. Prepare the cable end 
and wires for connection allowing sufficient bare conductor to enter the terminal fully.  
 
Connect the incoming wires as follows: 
• Red to DC positive 
• Black to DC negative 

COMPLETING

 

THE

 

CONNECTIONS

 

AND

 

POWERING

 

UP

Once all the connections have been made as detailed in the Installation section of this 
user guide and the same corresponding section of the light source user guide, connect 
mains power to the enclosure (AC version) or the remote PSU (DC version). If no light is 
produced consult the TROUBLESHOOTING section in this manual and the light source 
manual.

Summary of Contents for IP-04

Page 1: ...PRODUCT USER GUIDE IP 04 Weatherproof Enclosure PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE ENCLOSURE Rev C1...

Page 2: ...person familiar with the construction and operation of the product and the hazards involved When used in the USA or Canada cables connected to this enclosure must be UL listed and not only suitable f...

Page 3: ...the environment location in which the PSU is to be installed 2 Mains supply 240V 50 Hz denoted by the model number having the suffix AC For Comet this version has the light source 48V DC PSU mounted i...

Page 4: ...INTRODUCTION FIGURE 1 AC SCHEMATIC USING COMET LIGHT SOURCE IP 04 WEATHERPROOF ENCLOSURE USER GUIDE 4...

Page 5: ...INTRODUCTION FIGURE 2 24V DC SCHEMATIC USING COMET LIGHT SOURCE 5 UFO LIGHTING...

Page 6: ...INTRODUCTION FIGURE 3 AC SCHEMATIC USING QUASAR LIGHT SOURCE IP 04 WEATHERPROOF ENCLOSURE USER GUIDE 6...

Page 7: ...INTRODUCTION 7 UFO LIGHTING DIMENSIONS Note that dimensions are shown in mm...

Page 8: ...48V DC 60W Ordering Code Control Options Power Variant Total Power UFO IP04 QUA CT1 80 X AC Manual DMX 0 10V 1 10V 240VAC 50Hz 150W UFO IP04 QUA CT2 90 X AC Manual DMX 0 10V 1 10V 240VAC 50Hz 150W UF...

Page 9: ...240VAC 50Hz 150W UFO IP04 QUA CT2 90 T AC Manual DMX 0 10V 1 10V 240VAC 50Hz 150W UFO IP04 QUA CT1 80 CF AC Manual DMX 0 10V 1 10V 240VAC 50Hz 150W UFO IP04 QUA CT2 90 CF AC Manual DMX 0 10V 1 10V 240...

Page 10: ...rientation detailed below The enclosure must be located out of direct sunlight and there must be a minimum of 300mm 12 of space around all sides to allow for air circulation and to prevent overheating...

Page 11: ...ote that unless UFO are installing the unit then we do not supply fixings This is due to the large variance of surface types the enclosure may be mounted to 4 Follow the instructions for the chosen fi...

Page 12: ...re tightening the gland to create a seal Do not overtighten the nylon gland Never run the luminaire with the fibre optic harness out of the aperture Loosen the gland for the DMX or 0 10V cables and fe...

Page 13: ...cables and feed the cables carefully through the gland leaving sufficient slack inside the enclosure to reach the back of the light source Tighten the gland and fit RJ45 or XLR connectors to the cabl...

Page 14: ...t power indicator on PSU is lit Voltage drop in DC cable too great Check DC output at PSU and at terminal block in the enclosure Increase size of cable or mount PSU closer to the enclosure Wiring inco...

Page 15: ...age 48V DC Comet Quasar is not compatible with DC supply LED Power Max 60W Comet 60W Quasar Control Options Comet DMX Manual 0 10V 1 10V Dali Quasar DMX Manual 0 10V 1 10V TECHNICAL INFORMATION Note t...