background image

INTRODUCTION

IP

-

04 WEATHERPROOF

 

ENCLOSURE

 

USER

 

GUIDE

2

Thank you for purchasing this UFO weatherproof enclosure which is fitted with an LED light 
source unit. 
 
To ensure the enclosure is mounted and connected correctly please read this user guide before 
installing and operating or performing any maintenance on the enclosure. To ensure that the 
light source within the enclosure is set up optimally and gives a long service life, please read the 
light source user guide supplied with the enclosure before installing operating or performing 
any maintenance on the unit. 
 
Please keep both these guides for future reference. 
 
This user guide is laid out in 3 sections: 
 

Introduction

 - information on the enclosure and its light source. 

Installation 

- details on how to install and power up the enclosure 

                             (supplements the light source guide). 

Maintenance

 - maintenance log, troubleshooting guide, technical specification.

IMPORTANT

This product must be installed in accordance with the applicable installation code, by a person 
familiar with the construction and operation of the product, and the hazards involved. When 
used in the USA or Canada, cables connected to this enclosure must be UL listed and not only 
suitable for functional purposes but also for the environment/location in which the enclosure is 
installed. 
 

Type Y Attachment: 

If the external flexible cable or cord of this luminaire or associated 

PSU/driver is damaged, it shall be exclusively replaced by the manufacturer or his service agent 
or a similar qualified person to avoid a hazard. 
 

Location: 

This enclosure must be located out of direct sunlight and away from areas prone to 

flooding. 
 

Circulation: 

It is imperative that a gap of at least 300mm is left around the unit and it is located 

away from any other heat source. This is to allow air to circulate and prevent overheating. The 
location must have free ventilation and must not have an ambient temperature higher than 
that specified for the unit. 
 

Mounting: 

This enclosure should be fixed upright to a vertical surface only, with sufficient gap 

at the front to allow the enclosure lid to be opened the full 130° for internal access. 
 

Seal Integrity: 

Always close and secure the enclosure door after access.

Summary of Contents for IP-04

Page 1: ...PRODUCT USER GUIDE IP 04 Weatherproof Enclosure PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE ENCLOSURE Rev C1...

Page 2: ...person familiar with the construction and operation of the product and the hazards involved When used in the USA or Canada cables connected to this enclosure must be UL listed and not only suitable f...

Page 3: ...the environment location in which the PSU is to be installed 2 Mains supply 240V 50 Hz denoted by the model number having the suffix AC For Comet this version has the light source 48V DC PSU mounted i...

Page 4: ...INTRODUCTION FIGURE 1 AC SCHEMATIC USING COMET LIGHT SOURCE IP 04 WEATHERPROOF ENCLOSURE USER GUIDE 4...

Page 5: ...INTRODUCTION FIGURE 2 24V DC SCHEMATIC USING COMET LIGHT SOURCE 5 UFO LIGHTING...

Page 6: ...INTRODUCTION FIGURE 3 AC SCHEMATIC USING QUASAR LIGHT SOURCE IP 04 WEATHERPROOF ENCLOSURE USER GUIDE 6...

Page 7: ...INTRODUCTION 7 UFO LIGHTING DIMENSIONS Note that dimensions are shown in mm...

Page 8: ...48V DC 60W Ordering Code Control Options Power Variant Total Power UFO IP04 QUA CT1 80 X AC Manual DMX 0 10V 1 10V 240VAC 50Hz 150W UFO IP04 QUA CT2 90 X AC Manual DMX 0 10V 1 10V 240VAC 50Hz 150W UF...

Page 9: ...240VAC 50Hz 150W UFO IP04 QUA CT2 90 T AC Manual DMX 0 10V 1 10V 240VAC 50Hz 150W UFO IP04 QUA CT1 80 CF AC Manual DMX 0 10V 1 10V 240VAC 50Hz 150W UFO IP04 QUA CT2 90 CF AC Manual DMX 0 10V 1 10V 240...

Page 10: ...rientation detailed below The enclosure must be located out of direct sunlight and there must be a minimum of 300mm 12 of space around all sides to allow for air circulation and to prevent overheating...

Page 11: ...ote that unless UFO are installing the unit then we do not supply fixings This is due to the large variance of surface types the enclosure may be mounted to 4 Follow the instructions for the chosen fi...

Page 12: ...re tightening the gland to create a seal Do not overtighten the nylon gland Never run the luminaire with the fibre optic harness out of the aperture Loosen the gland for the DMX or 0 10V cables and fe...

Page 13: ...cables and feed the cables carefully through the gland leaving sufficient slack inside the enclosure to reach the back of the light source Tighten the gland and fit RJ45 or XLR connectors to the cabl...

Page 14: ...t power indicator on PSU is lit Voltage drop in DC cable too great Check DC output at PSU and at terminal block in the enclosure Increase size of cable or mount PSU closer to the enclosure Wiring inco...

Page 15: ...age 48V DC Comet Quasar is not compatible with DC supply LED Power Max 60W Comet 60W Quasar Control Options Comet DMX Manual 0 10V 1 10V Dali Quasar DMX Manual 0 10V 1 10V TECHNICAL INFORMATION Note t...

Page 16: ...bH Andreasstra e 20 93059 Regensburg Deutschland 49 0 9491 955880 www ufo licht de Universal Fiber Optics USA LLC 1749 Northgate Blvd Sarasota FL34234 USA 941 343 8115 www fiberopticlighting com Unive...