background image

6

USE

Attach the base firmly to the feet of the unit and check that the splash guard is properly in place 

and that it is not in contact with the heating element. Check that the unit stands horizontally. 

Unlock he cover by turning the locking knob 90 degrees in either direction and pulling it then 

up. Fill the container with clean and warm water. [It will take longer for cold water to vaporize.] 

Close the cover, push the locking knob down and turn it  90 degrees in either direction. The float 

indicates the level of water. Be careful not to splash water on the controls or on the floor when 

filling the container. The water in the container is hot. WARN AND LOOK AFTER CHILDREN. 

Never use the humidifier if the cover is not properly locked.

Avoid moving the humidifier when it is filled. The temperature of the water in the container is 65 

to 80°C and the temperature of the vapor 50 to 60°C. Current output is 160 or 320W/230V. Water 

container capacity is 5,6 liters.The recommended relative humidity of indoor air is 30 to 45 %. 

Use Ufox Control HC-1 automatic humidity guard if required. Plug the humidifier to a grounded 

socket and set the operating switch to desired position. In position 1 the vaporizing effect is 0.4 

liters/hour and in position ½ the effect is 0.2 liters/hour. The indicator light is on when the unit is 

in operation. Turn the humidifier off by turning the operating switch to position 0. The indicator 

light goes off. If the indicator light does not go on even when operating position is selected and 

the humidifier is plugged into mains, press the Start switch down.

The humidifier is switched off automatically and the indicator light goes off when the level of 

water drops to the level of the heating element. After refilling with water, start Ufox by pressing 

the Start switch. The humidifier cannot be restarted when it is hot.

If the humidifier will be out of use for a long time, empty the container and dry it. After years 

of use and after a long time out of use in particular, the rubber seals may lose some of their 

elasticity. When using the unit again, before connecting the power, check the seals to avoid leaks 

and consequential damages to the unit and even the floor if leaks should occur.

CLEANING

Impurities and minerals of water deposit on the bottom of the container and on the surface of 

the heating element. Empty the remaining water regularly to slow down the calcifying process. 

Disconnect your Ufox from the mains and clean it as follows:

Empty the water container.

• 

Dissolve the crust of lime using Ufox cleaning solution: Pour 1 liter of clean and warm water 

• 

in the container until the heating element is covered. Add 0.5 liter of cleaning solution into the 

container.

The humidifier must not be connected to the mains while it is being cleaned.

• 

Be careful not to allow any water or cleaning solution in the electric controls.

• 

Allow  the  solvent  to  work  for  2  to  20  hours  in  a  well-ventilated  place  with  no  access  to 

• 

children.

Pour the used solution in the sewer.

• 

Rinse the container thoroughly. Use a soft brush if necessary. Be careful not to allow any 

• 

water in the controls.

The material safety data sheet for the Ufox cleaning solution is available, for example, at 

• 

www.ufox.fi or via email from info@allaway.fi.

A crust of lime less than 2 mm does not affect the functioning of the unit. When not in use, 

• 

clean the humidifier before storing it.

Summary of Contents for 3S

Page 1: ...Ufox 3 S ilmankostuttimen k ytt ohje Ufox 3 S luftfuktare Bruksanvisning Ufox 3 S Humidifier instructions for use...

Page 2: ...nkil iden k ytt n joilla on alentuneet fyysiset aistimukselliset tai psyykkiset kyvyt Ohjaa ja valvo laitteen k yt ss isompia lapsia ja henkil it joilla on puutteita kokemuksessa ja taidoissa Placera...

Page 3: ...tutin kytkeytyy automaattisesti pois p lt kun veden pinta laskee l mp elementin tasalle T ll in merkkivalo sammuu Veden lis yksen j lkeen paina START kytkint jolloin kostutin kytkeytyy p lle Kuuma koj...

Page 4: ...visas av en flott r Undvik att spilla vatten p elektriska delar eller omr det omkring apparaten vid p fyllningen Vattnet i beh llaren hett VARNA OCH SE EFTER BARNEN Locket skall alltid l sas n r luftf...

Page 5: ...kontakt med elektriska delar Skyddsinformationsbladet f r Ufox reng ringsmedel finns att f bl a p webbadressen www ufox fi eller via e post p adressen info allaway fi Ett kalklager tunnare n 2 mm inve...

Page 6: ...humidifier is switched off automatically and the indicator light goes off when the level of water drops to the level of the heating element After refilling with water start Ufox by pressing the Start...

Page 7: ...s required for repairs under guarantee Repairs shall be carried out by an authorized Allaway servicing company WARRANTY OF CONSISTENCY WITH EU DIRECTIVES FOR ELECTRICAL APPLIANCES Allaway Oy Kangasvuo...

Page 8: ...I SE UK Rev04 11 2009 S ilyt ohje tallessa my hemp k ytt varten Spara instruktionen f r senare bruk Keep the instructions for further use P O Box FIN 40351 JYV SKYL www ufox fi www allaway com info al...

Reviews: