Gas Detector Setup
There are common gas detector settings in the
[GAS_DETECTOR]
section. Check whether
minimum and maximum values correspond to your needs:
[GAS_DETECTOR]
MIN_CONCENTRATION_PPM=0
MAX_CONCENTRATION_PPM=1000
These values are used to bound valid gas detector values. When the gas concentration is out
of the limits, the operator will be notified.
Another parameter to be set is the sensor’s background value:
[GAS_DETECTOR]
ZERO_LEVEL_PPM=0
The
ZERO_LEVEL_PPM
value will be subtracted from the gas concentration reported by the
gas detector resulting in the true gas concentration.
Pergam Laser Falcon Setup
1. Set
PERGAM_FALCON
item to
true
in
[PAYLOADS]
section:
[PAYLOADS]
PERGAM_FALCON=true
2. Choose the appropriate
SERIAL_DEVICE
in the
[PERGAM_FALCON]
section:
[PERGAM_FALCON]
SERIAL_DEVICE=/dev/ttyUSB0
See
Pergam Laser Falcon Configuration
to find all available settings with default values and
descriptions.
Pergam LMm Setup
1. Set
PERGAM_LMM
item to
true
in
[PAYLOADS]
section:
[PAYLOADS]
PERGAM_LMM=true
Gas Detector Setup
UgCS SkyHub User Manual
Copyright © 2019—2021, SPH Engineering
70
Revision 5 • November 2021