3. Set the
MIN_SENSOR_DEPTH_M
parameter in the
[ECHOLOGGER_ECT]
section for
data filtering by echosounder depth value while recording. Set to zero for disabling:
[ECHOLOGGER_ECT]
MAX_SENSOR_ANGLE_DEG=10
MIN_SENSOR_DEPTH_M=0.1
4. Set the
RANGE_M
, the
DEADZONE_MM
parameters in the
[ECHOLOGGER_ECT]
section
according to the water body to be explored:
[ECHOLOGGER_ECT]
DEADZONE_MM=300
RANGE_M=10
5. One may choose the output data format for Echologger ECT400. The
NMEA
value is
useful when only NMEA log file should be recorded. The
ECHOSOUNDER
mode is used
to record both NMEA and SEG-Y logs:
[ECHOLOGGER_ECT]
MODE=NMEA
; or
MODE=ECHOSOUNDER
Note the data rate in the
ECHOSOUNDER
mode is significantly lower than in the
NMEA
one.
Table 13.1 — Maximum data rate against range in NMEA and Echosounder mode for Echologger ECT400
Range
NMEA mode
Echosounder mode
2 m
10 Hz
4 Hz
10 m
10 Hz
2 Hz
20 m
1 Hz
40 m
5 Hz
80 m
4 Hz
0.5 Hz
100 m
3 Hz
0.4 Hz
See
Echologger ECT400 Configuration
to find all available settings with default values and
descriptions.
Echologger ECT D052/D032 Setup
Echosounder Setup
UgCS SkyHub User Manual
Copyright © 2019—2021, SPH Engineering
67
Revision 5 • November 2021