Instructions for use (rev 05/18)
e.ON SINTER
UGIN DENTAIRE
39
6.7.
Positioning the elements and starting the cycle
1)
Positioning of support
-
For use the furnace, always place the support on the platform. Use only the original support
e.ON SINTER – UGIN DENTAIRE.
-
Before use, check if it is in perfect condition: presence of dirt or damage. Clean with brush if
necessary (see chapter 8 - Maintenance). If the support is damaged or cracked, do not use
and replace it.
-
It is composed of a base and a floor. According to the number of tray for sinterizing to
position, it is necessary to place or remove the floor:
2)
Positioning of elements and tray for sinterizing
-
Empty a zirconia pearls into a tray (a layer at the bottom is sufficient to prevent the
elements from rubbing on the bottom and sides).
-
Place the elements in a tray (avoid touch amongst themselves), then place the cover.
-
The three trays can be stacked. According to yours needs, you can stack 2 or 3 trays. Always
place the cover on the last tray.
-
Place the tray(s) at the centre of support.
Note: for 60 elements.
Beads for sintering must be changed in any tray if a
discoloration in yellow color appears
Tray for sinterizing with cover
Number of tray to place
Support to place
1
base + floor
2
base + floor
3
base
IMPORTANT: observe these indications
so as not to exceed the maximum height
(risk of damage)
Summary of Contents for e.ON SINTER
Page 2: ......