Instructions for use
(rev 150620)
e.ON
UGIN DENTAIRE
12
6.
USE AND CONFIGURATION
6.1.
WORKING INTERFACE
Following power up, the initialization interface appears on the screen.
The main screen automatically appears: menu
“Working interface”.
6.2.
CONTROL KEYS
PICTURES
KEYS
DESCRIPTION
Start cycle
(RUN)
The selected program is started.
Pause
(HOLD)
In running state, the program will be in a suspended state, the
temperature remains constant.
Stop
(STOP)
Under operating state or suspended state, the program will end.
Ascent platform
(ARROW KEY
UPWARD)
Press this key, the platform will rise, press again, the platform will
stop at the desired level.
Descent platform
(ARROW KEY
DOWNWARD)
Press the key, the platform go down, press again, the platform will
stop at the desired level.
NOTE: if the furnace temperature is above 300°C, it is not possible
to start a cycle (risk of damages the insulation materials). Then,
press descent platform key (ARROW KEY DOWNWARD): an alert
message appears in the status bar (bottom of the screen).
Menu
(MENU or logo
Microsoft)
Pull-down menu appears, as shown below:
Working interface
Parameters current cycle display.
Real-time curve
Display of the cycle curve (temperature/time).
Program editor
Program settings.
Parameter setting
Software settings. Only access with technician code (reserved for
technicians customer’s service UGIN DENTAIRE).
Language selection
Available languages: English, French, Spanish and Italian.
Date setting
Setting the date, time and day of the week.