Instructions for use (rev 031121) - En
PROGRAMIX 50 - 100
UGIN DENTAIRE
12
▪
3
rd
STAGE
o
Rate No. 3 (RP 3): from 1 to 15°C/min
–
FULL - STOP
Temperature rise to the 3
rd
stage.
o
3
rd
stage temperature: from 0 to 1200°C
Temperature setting for the 3
rd
stage
o
Hold time from 0 to 240 min
Hold time for the temperature of the 3
rd
stage.
▪
DELAY FINAL: FROM 0 TO 240 MIN
This timer function sets a time delay before the firing cycle is stopped completely.
Once you have programmed your full cycle, you may program the furnace hold at the last temperature for 0
to 240 min, in addition to the hold time.
This means that you can choose the time you need to perform your castings.
5.5.
PROGRAM NUMBER DISPLAY
If the control station is on stand-by, the program number can be changed using the keys
and
The control station has a storage capacity of 30 programs.
-
Programs 0 to 19 are 3-stage programs.
-
Programs 20 to 29 are a double 6-stage programs.
The program number cannot be changed while the furnace is in operation (the program number blinks, key
enabled) or when the cycle has begun (
key enabled).
5.6.
TEMPERATURE/TIME DISPLAY
This display gives you the value of the parameters while setting up the program. During the heating cycle,
you can choose to display either:
-
the temperature during the heat rise and the countdown during the hold periods,
-
or the temperature only.
ln that case, press the
key. A dot then appears at the far right of the display (No. 3) to indicate that
you have chosen the temperature mode.
5.7.
INDICATOR OF THE UNIT DISPLAYED ON THE PANEL (No. 3)
Two red lights indicate units of temperature and heating rate: °C and °C /min. Two green lights indicate units
of time: hours and minutes.
5.8.
MODE KEY
This key
is pressed to switch from the temperature/time display mode to the temperature only
display mode.
5.9.
FORWARD AND REVERSE KEY
ln
stand-by position
, pressing one of the increment/decrement keys modifies the program number.