Instructions for use (rev 031121) - En
PROGRAMIX 50 - 100
UGIN DENTAIRE
17
9.
MAINTENANCE AND TROUBLE-SHOOTING
Before to carry out the maintenance work and/or cleaning:
-
disconnect from the main power supply
(switch OFF and unplug to mains socket),
-
wait the cooling
at room temperature
after use
(risk of burns and/or damage).
9.1.
MAINTENANCE
Observe the following recommendations to ensure the longevity of the device:
-
Clean the machine outside with a soft, dry cloth.
-
Do not use abrasive, solvents or flammables products for cleaning (outside and inside).
-
Visual inspection of
heating chamber and refractory plate
before use.
If necessary, clean with a vacuum cleaner to remove any particles (dust) - do not use compressed air.
If damaged or cracked: do not use and replace-it.
-
PRECAUTIONS FOR USE
: some investments (alcohol based) are extremely aggressive to the heating
elements of the muffle and the thermocouple.
To avoid premature wear of these elements, we recommend to
preheat the cylinders in a special
preheating furnace at 200°C for 1 hour
. If you do not have a preheating furnace, you can also use a
metallic heating platform used on a gas stove for 20 to 30 minutes.
IMPORTANT
: we recommend to
keep a thermocouple in reserve
, to avoid the furnace’s
immobilization due to wear of this element.