Instructions for use (rev 031121) - En
PROGRAMIX 50 - 100
UGIN DENTAIRE
9
4.2.
INSTALLATION
NOTE: for marks, see chapter A
–
equipment description.
-
Install in a ventilated room. Observe the conditions indicated in chapter 3.2.
-
Place the furnace on a flat, level and clear surface. Keep a distance from other objects around not less
than 10 cm. Keep it away from heat sources (radiators and/or other equipment that release heat). Avoid
vibrations and shocks
-
Dust, corrosive or explosive gases can damage the body and the insulation.
-
The furnace must not be used or placed in a place where there is a risk of explosion.
-
Its forbidden placing inflammables, toxic, volatile or explosives around the furnace.
This unit requires its own power line and has to be connected to a circuit breaker. Grounding
is mandatory
to avoid accidents and the dangers of overheating the power line.
Connect it
directly to the primary socket
, do not use multiple sockets (risk of electrical interference).
▪
Fumes extractor installation
UGIN DENTAIRE recommends installing a fumes extractor on the PROGRAMIX 50 / 100 in order to achieve
optimal gas evacuation. It will be installed in place of the chimney outlet. It is recommended to use the
UGIN
DENTAIRE fumes extractor
.
Installation procedure to UGIN DENTAIRE fumes extractor:
-
Remove the chimney outlet (No. 1): unscrew.
-
Instead install the fumes extractor: screw.
-
Connect it to the fumes extractor connection socket (n ° 4).
-
Through this connection, the fumes extractor is connected with the furnace programmer which will start
and stop it as needed.
IMPORTANT:
PROGRAMIX 50/100
can be connected a fumes extractor or extractor hood within or
without external control independent of the furnace and a
maximum power of 20W
.
If non-observance of these instructions: risk of material damage (overintensity) and may voids any
warranty for your device.
4.3.
START-UP
NOTE: for marks, see chapter A
–
equipment description.
-
Connect the power cord to the power socket (No. 3).
-
Make sure that the mains voltage complies with the voltage indicated on the rating plate, connect the
power cord to a 10/16 A grounded power socket.
-
Activate the ON/OFF switch (on the right side).