SAFETY

CONSIDERATIONS

Your science, our devices

More than 30.000 citations

The Librae Incapacitance Tester has 

been designed and approved in 

accordance with international safety 

standards. 

Please follow the safety instructions, 

cautions and warnings in this manual 

to ensure safe operation and to retain 

the instrument in a safe condition.

The instrument cover must not be 

opened or removed. Capacitors inside 

the instrument may be charged, even 

even after it has been disconnected 

from all power sources. 

Product service and repair must be 

performed by qualified personnel 

authorized by the Ugo Basile 

organization.

Instruction Manual

July 2020 Revision 2.2

       

MOD. 13 Rev. 1

 

 

 

CE CONFORMITY STATEMENT 

 

Manufacturer 

UGO BASILE srl 

Address 

Via G. di Vittorio, 2 – 21036 Gemonio, VA, ITALY 

Phone n. 

+39 0332 744574    

Fax n. 

+39 0332 745488 

Email 

support@ugobasile.com 

We hereby declare that 

 

Instrument. 

Librae Incapacitance tester for mice and rats  

SKU  

47883/47882/47885/47880-001 

 

 

 

 

is manufactured in compliance with the following European Union Directives 

 and relevant harmonized standards 

 

2006/42/CE on machinery

 

 

2014/35/UE  relating to electrical equipment designed for use 

within certain voltage limits 

 

2014/30/UE relating to electromagnetic compatibility 

 

2011/65/UE and 2015/863/UE on the restriction of the use of certain hazardous substances in 
electrical and electronic equipment

 

 

Account Manager 

Mauro Uboldi 

 

         

Nome / Name 

 

July 2020 

 

 

Date

  

Firma / Signature    

 

Summary of Contents for 47880-001

Page 1: ...Instruction manual Librae Incapacitance tester July 2020 revision 2 2 SKU 47883 47882 47885 47880 001 Pain Inflammation...

Page 2: ...organization Instruction Manual July 2020 Revision 2 2 MOD 13 Rev 1 CE CONFORMITY STATEMENT Manufacturer UGO BASILE srl Address Via G di Vittorio 2 21036 Gemonio VA ITALY Phone n 39 0332 744574 Fax n...

Page 3: ...d of this manual and also at ugobasile com Product features What is in the box Librae package contents SKU 47883 The Librae Incapacitance tester for mice 1 transparent plastic restrainer for mice 1 Pe...

Page 4: ...e the weight averaged over a few seconds is normally used as the data point For example the device provides an index of discomfort in the osteoarthritic knee normally expressed as the Left Right weigh...

Page 5: ...th the Librae touch screen you may notice a different less sensitive response You may need to press slightly harder or use a stylus pen on the touch screen This is because we employ a resistive touch...

Page 6: ...e you are welcome to contact our Service Department see paragraph 5 4 Customer Support specifying the serial number of your instrument 3 3 Safety Instructions The following guidelines must be followed...

Page 7: ...e manufacturer Servicing carried out by unauthorized personnel See also paragraphs 2 1 1 and 2 1 2 3 8 Connection Connect the mains cord between the power socket of the Librae and the power outlet pro...

Page 8: ...might take up to 60 seconds During this time the UB logo and product name will be displayed Figure 4 0 1 Figure 4 0 1 4 1 Home Page When the start up is finished the Home Page Menu is displayed Figur...

Page 9: ...l has entered the restrainer tilt the restrainer back down to the flat position 8 When ready press START button or pedal switch to run the experiment 6 1 If Autostart Mode is enabled wait for the inst...

Page 10: ...text field to enable a virtual keyboard Figure 4 2 2 This is an alphanumeric field enter a maximum of 12 characters Figure 4 2 2 Characters Virtual Keyboard Figure 4 2 3 Numeric Virtual Keyboard PROT...

Page 11: ...the restrainer and if the experiment is running correctly Figure 4 4 1 Ehorizontal lements displayed on the START page from left to right provide the following functionality 1 i INFO button This butto...

Page 12: ...start Autostart is a unique Librae Incapacitance Tester feature By selecting this operative mode Librae helps the user to perform the experiment in a consistent way reducing variability and user bias...

Page 13: ...tabilization AUTO icon is YELLOW When ALL the autostart requirements are completed the experiment automatically starts Figure 4 6 5 Figure 4 6 5 Autostart is waiting for stabilization time to elapse A...

Page 14: ...or update system icon refer to paragraph 4 1 1 5 Press Update button and wait for a reboot Figure 4 7 1 1 Now the Librae Incapacitance Tester is up to date An Erase DB could be necessary Refer to para...

Page 15: ...ton shows Figure 4 7 5 1 the results of the experiments stored inside Librae Incapacitance Tester Every result box contains 1 Date and time of the experiment 2 Treatment ID protocol stage and trial 3...

Page 16: ...gure 4 8 1 1 and Table 4 8 1 1 for connector pinout Figure 4 8 1 1 DB 15 Pin Signal Name Signal Type Description 1 Start Stop TTL OUT Start TTL High Level Stop TTL Low Level 2 Manual Autostart TTL OUT...

Page 17: ...not hesitate to contact our service department or our local distributor either directly of via our support page Before sending any instrument to our factory for repair please contact our logistics dep...

Page 18: ...paratus Thermal Place Preference TPP Test for Mice Rats Analgesy Meter the 1st and original Randall Selitto paw pressure test Other Ugo Basile products related to this device visit ugobasile com web s...

Page 19: ...torio 2 21036 Gemonio VA ITALY Tel 39 0332 744574 sales ugobasile com The 1st original Mouse RotaRod for motory coordination studies Fear Conditioning System ANYmaze GSM Grip Strength Meter for mice a...

Reviews: