background image

4

ARCTIC DELUXE UL

1  TECHNICAL CHARACTERISTICS

Specifications are subject to change without notice.

2  INTRODUCTION

Please read all sections of this manual thoroughly to familiarize
yourself with all aspects of the unit.
Like all mechanical products, this machine will require cleaning
and maintenance. Besides, dispenser working can be
compromised by operator’s mistakes during disassembly and
cleaning. It is strongly recommended that personnel responsible
for the equipment’s daily operations, disassembly, cleaning,
sanitizing and assembly, go through these procedures in order
t o   b e   p r o p e r l y   t r a i n e d   a n d   t o   m a k e   s u r e   t h a t   n o
misunderstandings exist.

3  INSTALLATION

1

Remove the corrugate container and packing materials and

keep them for possible future use.

2

Inspect the uncrated unit for any possible damage. If

damage is found, call the delivering carrier immediately to file a
claim.

3

Install the unit on a counter top that will support the combi-

ned weight of dispenser and product 

bearing in mind what is

stated in the preceding point 1 IMPORTANT warning.

4

A minimum of 15 cm (6”) of free air space all around the unit

should be allowed to guarantee adequate ventilation.

5

Ensure that the legs are screwed tightly into the base of the

machine.
Replace the standard legs originally installed with the 100 mm
(4”) legs whenever they are provided with the unit.

6

Before plugging the unit in, check if the voltage is the same

as that indicated on the data plate. Plug the unit into a groun-
ded, protected single phase electrical supply according to the
applicable electrical codes and the specifications of your
machine. When the unit has no plug, install a proper grounded
plug, in compliance with electrical codes in force in your area,
suitable to at least 10 Amp 250 Volt (220-230 Volts 50-60 Hz
areas) and 20 Amp 250 Volt (100-115 Volts 50-60 Hz areas)
applications. Should you prefer to connect the unit directly to
the mains, connect the supply cord to a 2-pole wall breaker,
whose contact opening is at least 3 mm. Do not use extension
cords.

7

The unit doesn’t come presanitized from the factory. Before

serving products, the dispenser must be disassembled, clea-
ned and sanitized according to this handbook instructions
(chapter 5.3 CLEANING AND SANITAZING PROCEDURES).

4  TO OPERATE SAFELY

1

Do not

 operate the dispenser without reading this opera-

tor’s manual.

2

Do not

 operate the dispenser unless it is properly groun-

ded.

3

Do not

 use extension cords to connect the dispenser.

4

Do not 

operate the dispenser unless all panels are restrai-

ned with screws.

5

Do not

 obstruct air intake and discharge openings: 15 cm

(6”) minimum air space all around the dispenser.

6

Do not

 put objects or fingers in panels louvers and faucet

outlet.

7

Do not

 remove bowls, augers and panels for cleaning or

routine maintenance unless the dispenser is disconnected from

1/12
1/20

2/12
2/20

3/12
3/20

4/12
4/20

Transparent removable bowls

n

1

2

3

4

Capacity of each bowl, approx.

l

12
20

12
20

12
20

12
20

Dimensions:

 width

cm

18

36

54

72

depth

cm

47

47

47

47

height

12 lt
20 lt

cm

57
67

57
67

57
67

57
67

Net weight, approx.

12 lt
20 lt

kg

20
22

24
32

36
42

44
55

Gross weight, approx.

12 lt
20 lt

kg

22
25

28
36

40
46

49
59

Adjustable thermostats

n

1

2

3

4

Hermetic compressor

Air-cooled condenser

Overload protector

Noise level lower than 70 dB (A)

IMPORTANT

Read electrical ratings written on the data plate of the
individual units; the data plate is adhered on the dispen-
sing side panel of the unit, just behind the drip tray (the
right side drip tray in multiple bowl models). The serial
number of the unit (preceded by the symbol #) is adhered
just below the right bowl. Data plate specifications will
always supersede the information in this manual.

IMPORTANT

When handling the machine never grasp it by the bowls
or by the evaporator cylinders. The manufacturer refuses
all responsibilities for possible damages which may
occur through incorrect handling.

ATTENTION

Failure to provide proper electrical ground according to
applicable electrical codes could result in serious shock
hazard.

IMPORTANT

Install  the dispenser so that the plug is easily accessi-
ble.

Summary of Contents for arctic deluxe ul

Page 1: ...OPERATOR S MANUAL CARNET D INSTRUCTIONS MANUAL DE INSTRUCCIONES ARCTIC DELUXE UL...

Page 2: ...ARCTIC DELUXE UL 2...

Page 3: ...3 4 8 12...

Page 4: ...breaker whose contact opening is at least 3 mm Do not use extension cords 7 The unit doesn t come presanitized from the factory Before serving products the dispenser must be disassembled clea ned and...

Page 5: ...used in the dispenser 3 To shorten product cooling down time and increase produc tivity the bowl should be refilled after the product level drops lower than half and at the start of each day 4 The dis...

Page 6: ...warm 45 60 C 120 140 F sanitizing solution 100 PPM available chlorine concen tration or 1 spoon of sodium hypoclorite diluted with two litres of water according to your local Health Codes and manufac...

Page 7: ...Health Codes and manufacturer s speci fications 2 Pour the solution into the bowl s 3 Using a brush suitable for the purpose wipe the solution on all surfaces protruding above the solution level and...

Page 8: ...rupteur mural de type bipolaire avec ouverture des con tacts d au moins 3 mm Ne pas utiliser de rallonges pour bran cher lectriquement l appareil 8 Quand le distributeur sort de l usine il n est ni pr...

Page 9: ...en fonction de diff rents facteurs comme par exemple la temp rature ambiante et la temp rature initiale du produit 2 L efficacit du distributeur peut tre augment e en versant dans les r servoirs du p...

Page 10: ...rieure 4 Rincer toutes les pi ces lav es l eau courante 5 3 3 DESINFECTION DU DISTRIBUTEUR DEMONTE La d sinfection doit tre ex cut e imm diatement avant de mettre le distributeur en fonction Il faut...

Page 11: ...arer dans une bassine une solution d eau et de produit d sinfectant approuv par les autorit s de votre Pays en res pectant les indications du producteur En l absence d un produit d sinfectant sp cifiq...

Page 12: ...ared de tipo bipolar con apertura de contactos de 3 mm por lo menos No utilizar cordones conectores para enchufar el aparato al suministro de corriente el ctrica 8 El distribuidor no sale de f brica p...

Page 13: ...tores como por ejemplo la temperatura ambiente y la temperatura inicial del producto 2 Llenando los contenedores con producto ya enfriado previamente se incrementa la eficiencia del distribuidor 3 Par...

Page 14: ...r bastante No utilizar detergentes abrasivos 2 Emplear un cepillo apropiado y lavar minuciosamente con la soluci n detergente todas las partes en contacto con la bebida 3 Enjuagar todas las partes con...

Page 15: ...de un producto para higienizar espec fico preparar una soluci n de agua e hipoclorito de sodio lej a uso alimenticio en la proporci n de 1 cucharadita por cada 2 litros de agua 2 Verter la soluci n en...

Page 16: ...16 ARCTIC DELUXE UL SPARE PARTS LIST LISTE DES PIECES DE RECHANGE DESCRIPCION PIEZAS DE REPUESTO...

Page 17: ...d bit Palanca de mando grifo 30 21125 00000 Switch Interrupteur Interruptor 31 22800 05100 Switch cap Capuchon interrupteur Protecci n interruptor 32 22800 00300 Side panel Panneau lat ral Panel later...

Page 18: ...nterrupteur Interruptor 2 3 4 5 Thermostat Thermostat Termostato 6 7 8 9 Pump mixer switch Interrupteur pompe brasseur Interruptor bomba agitador 10 11 12 13 Pump mixer Pompe brasseur Bomba agitador 1...

Page 19: ...19 NOTES NOTES NOTAS...

Page 20: ...Ugolini spa Via dei Pioppi 33 20090 Opera MI Tel 02 530059 1 Fax 02 530059260 www ugolinispa com E Mail sales ugolinispa com 2408_29 V0 3 06E30...

Reviews: