Connection
Connector
Housing
Cable
d
External switch-
off
0.13 in. jack
plug
Socket
a b
8.2 ft. 3-wire (cable included in delivery)
a
Input (+)
RD (red)
b
Ground (GND)
BK (black) / WH (white)
M12 x 1,
A coded
(optional)
Plug
1 = Input (+)
BN (brown)
2 = Ground (GND)
WH (white)
e
Level input
0.13 in. jack
plug
Socket
ab c
Manufacturer's accessories
a
Main alarm
RD (red)
b
Pre-alarm
WH (white)
c
Ground (GND)
BK (black)
M12 x 1,
A coded
(optional)
Plug
1 = Pre-alarm
BN (brown)
2 = Main alarm
WH (white)
3 = Ground (GND)
BU (blue)
f
External control
RCA
Socket
a b
4.9 ft. 2-wire (cable included in delivery)
a
Input (+)
BN (brown)
b
Ground (GND)
WH (white)
CSA version
Plug
4.9 ft., 3-wire (cable included in delivery)
1 = input (+)
BN (brown)
2 = -
BK (black)
3 = ground (GND)
BU (blue)
M12 x 1,
B coded
(optional)
Plug
1 = ground (GND)
BN (brown)
2 = pulses
WH (white)
3 = pulses
BU (blue)
4 = ground (GND)
BK (black)
NOTICE!
The protection class of the control unit is only ensured if the connection ports are protected by caps or the standard connectors are inserted.
29
Diaphragm Dosing Pump
Encore
®
MB/ME
Operating Instructions
CF.450.410.001.IM.1114
Summary of Contents for Encore MB
Page 3: ...3 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 48: ...48 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 50: ...19 Notes 50 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 51: ...51 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 52: ...Encore MB ME Diaphragm Dosing Pump MANUAL NO CF 450 410 001 IM 1114 CF 450 420 001 IM 1114 ...