background image

 

Umwelt-Geräte-Technik GmbH

  |  Eberswalder Str. 58  |  D-15374 Müncheberg  |  Tel.: +49 (0) 33 43 2 - 89 575 |  

www.ugt-online.de

          Seite 9 von 17 

The sensors are watertight and can also be buried in the ground.  For the UMP-1-BT version, 

a maximum depth of 50 cm to be able to receive the Bluetooth signal. Depending on the soil 

type, the water content and the Bluetooth receiver the maximum installation depth may 

vary. Prior to installing several sensors deeper than 50 cm it is recommended to test the 

operation of the data transmission with a single sensor. 

6.

 

Operation 

To guarantee an effective use  the UMP-1 is available in two different types. Standard  as 

UMP-1 BT for installation in the field at different, maybe even hard to reach sites. And as 

UMP-1 BTim for measurement campaigns with many single measurements spread over a 

wide area. With a diameter of 5 mm the pins are bigger but also more robust than the pins 

of the standard type. The guidance of the pins additionally prevents damages of the pins 

during penetration of the soil. The extension of the probe with handle bar and smartphone 

bracket enables fast work for taking many single measurements in a row. 
Despite the different design the two probes hardly vary in the basics of operation just in the 

practical adjustment to their core tasks. 
 
 
By pressing the button on top of the 

sensor briefly the sensor is switched on. 

The red lighted status-LED shows the 

operating state of the sensor. After 

completion of the measurement/test 

series the sensor should be switched off 

by pressing the button long  (ca. 2s) to 

save power. Then the LED is no longer 

lighted. Only in the switched on state a 

Bluetooth connection can be 

established. 
 

Especially for fast done single measurements and anew penetration of the sensor into 

the soil each time special importance needs to be attached to the installation. 

 

For the measurement the antennas need to be completely in the soil. 

 

 

There must not be produced a gap  between antenna and soil (for example by 

movement of the sensor). 

 

 

The antennas have to be parallel and undamaged. The correct position of the 

antennas to each other is crucial for the accuracy of the measurement results. 

 

 

Be careful pushing the antennas into the soil. In case of hindrances don´t push 

further with more force but rather penetrate again at another spot. For very rigid soil 

better pre-drill.  

Button On/Off 

with status-LED 

Charge Socket 

Summary of Contents for UMP-1

Page 1: ...l UMP 1 BT Version 22 05 19 Umwelt Ger te Technik GmbH Eberswalder Str 58 D 15374 M ncheberg Tel 49 0 33 43 2 89 575 www ugt online de Seite 1 von 17 UMP 1 combined soil humidity conductivity and temp...

Page 2: ...nformation 5 2 1 Structure and basic function 5 2 2 Technical data 6 3 Volumetric water content of the soil 7 4 Mode of operation 7 4 1 Water content measurement 7 4 2 Electrical conductivity measurem...

Page 3: ...rement and time spent on installation and servicing In addition soil disturbance is reduced because only one sensor has to be installed in order to measure three soil properties In Addition to the cab...

Page 4: ...any questions or feedback Email info ugt online de or support ugt online de Phone 49 0 33432 89 575 Fax 49 0 33432 89 573 If contacting us by email or fax please include as part of your message your...

Page 5: ...be completely buried for a depth or horizontal installation It is made of plastic or stainless steel while the measuring rods antennas are always made of stainless steel Regular maintenance is not nec...

Page 6: ...24V DC Power input 60 mA Water content Measurement range 0 100 vol water content Accuracy 2 Resolution 0 1 vol water content Electrical conductivity Measurement range 0 001 4mS cm Optional measuremen...

Page 7: ...er to the FDR sensors nor the TDR sensors The basic mode of operation however corresponds to the FDR process because the sensor operates with a continuous signal at constant frequency 60 MHz and not w...

Page 8: ...ent is interrupted for a sort time and a signal in the kHz range transmitted over the antennae The corresponding IC measures the impedance of several different frequencies and averages the results 4 3...

Page 9: ...es fast work for taking many single measurements in a row Despite the different design the two probes hardly vary in the basics of operation just in the practical adjustment to their core tasks By pre...

Page 10: ...cap of the charge socket bajonet cap and connect the probe to either the USB port of your PC or a socket using the provided cable and adapter 7 Data output 7 1 App Installation The app is already inst...

Page 11: ...ity is available install a free file manager from the App Store for example the ES File Explorer and use this to click on the copied file 5 Select Install and follow the instructions on the screen 6 A...

Page 12: ...probes listed in this view are possible The use of Bluetooth restricts the maximum number of simultaneous connections to 7 although the actual app can manage more than 7 probes This dialogue also pro...

Page 13: ...ave been successfully implemented the dialogue closes and the main menu reappears If the dialogue does not close automatically a fault has occurred with at least one probe and is displayed in Box 2 of...

Page 14: ...t Temperature in C Conductivity mS cm a View as graph In this view mode the measured data are displayed as chart 30 measurements are always displayed simultaneously and continuously From 5 measurement...

Page 15: ...ts The recorded files are stored in the external memory of the device so that the files can be downloaded e g to a PC The first time recording takes place the folder UMP1 is created in the file system...

Page 16: ...reen orientation should be portrait or landscape Disable large images prevent large images such as background images being used in the app 7 3 Troubleshooting Error code Description Causes solutions 1...

Page 17: ...74 M ncheberg Tel 49 0 33 43 2 89 575 www ugt online de Seite 17 von 17 Can t access file 6 Fehler beim Datei lesen Can t read file 7 Falsches Dateiformat Wrong file format 8 Interner Systemfehler Int...

Reviews: