DAISY
26
1.
Description
1.1
Operation
The Power2 is a small and smart add-on Booster for both digital as well
as analog layouts.
It can be used:
•
along with a DAISY throttle (connected to the Power2 “DAISY”
connector) to form the “DAISY-System” in digital mode: a multi-
protocol digital Command Station
•
as an add-on Booster for digital Command Stations (either through a
LocoNet connection or through the 5-pole Booster connector)
•
as an analog train control system, when used with one or more
LocoNet throttles (e.g., a DAISY throttle, an IB-Control, a FRED, etc.)
•
as an additional power unit for driving one more sections of an analog
layout
•
as an intelligent “DCC turnout booster” (e.g., allowing DCC turnout
operation of an analog layout)
1.2 Technical Data
Max AC input voltage:
18 V
Output voltage range (adjustable):
15 V - 20 V
Max power output (current):
2 A
Max current output for LocoNet devices:
300 mA
Suggested transformer:
16 V / 45 VA
LocoNet output:
with Booster signal
1.3
Cables
Please use only original Uhlenbrock LocoNet cables or so-called
“standard” LocoNet cables. Failure to do so may cause a short circuit
when a train or a locomotive travels between layout sections powered
by different boosters.
1.4 Power 2 LED status
The Power2 LED indicates the Power2 status:
•
LED is always on
The Power2 is “on” (the power output has not been turned off)
•
LED is normally on. It is briefly off every 2 seconds
The power output has been turned off
•
LED flashes 4 times per second
A short, an overload or an overheating condition has been detected
(the power output has been turned off)
•
LED is normally on. It is briefly off every 1 second
A short or an overload condition has been detected on either the Loco-
Net or the “DAISY” connector (the power output has been turned off)
Summary of Contents for DAISY
Page 1: ......
Page 25: ...DAISY 25 Power 2...