4.8 Functions in analog mode
The function keys (f1 through f4) can be used to control features
pertaining to the driving characteristics of analog locomotives. Each
Power2 (each electric circuit) has its own setting, which is independent
of the setting applied to other Power2’s.
Function status can be edited through a LocoNet throttle controlling that
electric circuit (Power2).
[f1], [f2] acceleration/deceleration delay
[f1] off, [f2] off = minimum acceleration/deceleration delay
[f1] on, [f2] off = low acceleration/deceleration delay
[f1] off, [f2] on = medium acceleration/deceleration delay
[f1] on, [f2] on = maximum acceleration/deceleration delay
(Note: minimum delay means that a locomotive will react very quickly to
speed changes).
[f3] switching speed (i.e., half speed)
[f3] off = normal speed
[f3] on = switching speed (half of normal speed)
[f4] enable/disable acceleration/deceleration delay
[f4] off = acceleration/deceleration delay is enabled
[f4] on = acceleration/deceleration delay is disabled
[f5] motor control (low or high frequency)
[f5] off = low frequency (104 Hz) PWM (Pulse Width Modulation)
(e.g., for normal motors)
[f5] on = high frequency (16.7 KHz) PWM (Pulse Width Modulation)
(e.g., for coreless or Faulhaber motors)
[f7] loopback control
(check also section 4.6)
[f7] off = closing the Pin#1-#2 connection changes driving direction
breaking the Pin#1-#2 connection changes driving direction
[f7] on = closing the Pin#1-#2 connection changes driving direction
breaking the Pin#1-#2 connection does
not
change driving
direction
Summary of Contents for DAISY