CX2162/66
C
OMMISSIONING
13
5.2
Programming the service key
In its original condition (delivery status), the service key has not been memorized
by the knob module.
Waking the electronic cylinder by holding a key in front of the reader unit or
by turning the electronic knob module into the lock cylinder a few times. Upon
success, the electronic locking cylinder responds with three long audible
signals.
Within the next 15 seconds, the service key can now be programmed by
holding it in front of the electronic knob module. Once the service key has
been programmed successfully, the locking cylinder indicates this with two
short and one long audible signal.
After memorizing, the knob module enters the programming mode when the
service key is presented.
5.3
Management as programming / clearing system
5.3.1
Programming the key
Hold the service key in front of the reading unit of the knob module. The
knob module enters the programming mode.
Hold the key to be programmed in front of the reading unit until two short
audible signals indicate the success.
Optionally, program additional keys as described in the previous step.
Hold the service key in front of the reading unit or wait 15 seconds to exit the
programming mode.
To create a key with toggle authorisation, hold the key for 3 seconds in front of
the reading unit during the programming process until the success is indicated by
3 short audible signals.
5.3.2
Delete key
Hold the service key in front of the reading unit of the knob module. The
knob module enters the programming mode.
Hold the key to be deleted in front of the reading unit until two long audible
signals indicate success.
Optionally, delete additional keys as described in the previous step.
Hold the service key in front of the reading unit or wait 15 seconds to exit the
programming mode.
5.3.3
Delete all keys
Hold the service key in front of the reading unit of the knob module. The
knob module enters the programming mode.
Hold the service key until the knob module exits the programming mode.
Within 60 seconds, return the knob module to the programming mode and
hold the service key in front of the reading unit. In the meantime, the knob
module indicates success using short audible signals.
Once the programming mode is exited after 15 seconds, all the keys would
have been deleted.