CX2162/66
O
PERATION
15
6
Operation
6.1
Automatic wake up
The knob module is in sleep mode as long as it is not used. To check the
authorisation of a key, it needs to be woken up from the sleep mode. This
normally happens automatically when a key is held in front of the reader unit.
If, however, the knob module has been woken up 24 times (for example by
metallic objects in the surroundings) without reading a key, then automatic wake
up is disabled.
In this case the knob module has to be woken up manually.
Turn the knob module few times to wake up the reading unit, till an LED
starts glowing.
Hold up the key in front of the reading unit only after this.
The automatic activation is reactivated when an authorized key is scanned.
The wake up sensitivity (that is the number of times the knob module needs to be
turned to wake up the reading unit) can also be configured.