The electronic locking cylinder CX216x is a product in the Clex private system.
The reading unit, the communication electronics, the mechanical system and
power supply, are integrated within the knob module.
Different transponder carriers can be used as key in the CX216x, for example,
ISO card or key fob.
The CX216x has the following system properties:
Up to 1,000 key/locking authorizations can be stored
Up to 128 events can be recorded in the fitting
*
Up to 32 holidays can be configured
*
Automatic summer and winter time changeover
*
15 weekly schedules can be programmed
*
Permanent engagement possible without additional power consumption
Engagement time can be programmed from 1 to 15 seconds
Can be connected to the IDS module CX6934
Pre-configured by default for 868 MHz wireless networking
No cabling required
Can be combined with other systems (for example Clex prime)
Version for MIFARE
®
transponder available
Optional management via the CX2530 Keyng software
3.1.1
Battery management
The CX216x knob module comes with a battery management system, which
indicates the need for battery replacement by means of a visible and audio
signal, when the battery power reduces (capacity loss) during the final 1,000
operations of the battery (see chapter 7.2.1 Battery Replacement).
Signalling happens in three phases:
The battery needs to be changed soon.
If an authorized key is held in front of the knob module, the locking access right is
issued. The engagement is accompanied by red flashing (5x) and 5 brief audible
beeps.
The battery needs to be changed.
If an authorized key is held in front of the knob module, the knob module first
flashes green for 5 seconds, then the knob module engages. The engagement is
accompanied by red flashing (5x) and 5 brief audible beeps.
The battery needs to be changed immediately.
If an authorised key is held in front of the knob cylinder, the locking authorisation
is no longer issued. The knob cylinder flashes 5 times in red accompanied by 5
short beeps.
The access data, the events log, the settings of the knob module and the time are
stored on non-volatile memory and thus retained even when there is no power
supply, for example, when changing the battery or if the battery goes completely
flat. The time is written to the non-volatile memory once every 30 minutes. If the
power supply remains off, then the clock comes to a standstill after a few seconds
and starts running from the last stored value onwards after the power supply is
restored.
*
When CX2530 Keyng is used
Phase 1
Phase 2
Phase 3