CX2162/66
P
RODUCT DESCRIPTION
8
3.4
Technical data
3.4.1
General technical data
Name
Value
Dimensions of the
cylinder
For Europrofile locks conforming to DIN 18252
Cylinder lengths
CX2162
From 26/26 mm or 30/30 mm to 200/200 mm in
5 mm steps; over-sizes available upon request
Cylinder lengths
CX2166
From 30/10 mm 200/10 mm in 5-mm steps; over-sizes
available upon request
Length of the
electronic knob
44.3 mm
Diameter of the
electronic knob
31.4mm
Length of the
mechanical knob
20.0 mm
Diameter of the
mechanical knob
29.0mm
Transponder
Version 1: MIFARE
®
MIFARE
®
Classic, MIFARE
®
DESFire
®
,
Active transponder (868MHz)
Version 2: LEGIC
®
LEGIC
®
prime, LEGIC
®
advant, MIFARE
®
DESFire
®
,
Active transponder (868 MHz)
Power supply,
Nominal voltage
Battery CR2 3V (1 piece),
3 volt
Battery life
MIFARE
®
: up to 60,000 actuations or 5.7 years
LEGIC
®
: up to 50,000 operations or 8.6 years
3.4.2
Ambient conditions
Name
Value
Operating
temperature
+5°C to +55°C (indoor version)
-25°C to +65°C (outdoor version)
Storage temperature
-40°C to +65°C
Installation location
Indoor or outdoor (depending on the product model)
Protection class
IP55 (indoor version)
IP66 (outdoor version)