CX2172/4
T
ABLE OF CONTENTS
13
3.4
Technical data
3.4.1 General technical data
Name
Value
Minimum backset
Circular rosette: 28 mm
Oval rosette: 18 mm
Long narrow plate: 22 mm
Long wide plate: 33 mm
Door thickness
30 mm to 110 mm
Maximum door weight 300 kg
Swivel angle
45°
Transponder
MIFARE
®
Classic (868 MHz)
MIFARE
®
DESFire
®
(868 MHz)
Active transponder (868 MHz)
Radio
Frequency: 868.3 MHz
Maximum transmission power: 1 mW
Power supply,
Rated voltage
CR123A 3V battery (1 piece),
3 volts
Battery life
up to 170,000 operations or 9.8 years
Power consumption in
sleep mode
0.06 mW
3.4.2 Ambient conditions
Name
Value
Operating
temperature
+5°C to +55°C (indoor version)
-25°C to +65°C (outdoor version)
Storage
temperature
-40°C to +65°C
Maximum relative
humidity (door
handle)
Up to 95% non-condensing
Installation location Indoor or outdoor (depending on the product model)
Protection class
Indoor version: IP40
Outdoor version: IP66