CX6192
P
RODUCT DESCRIPTION
6
A Four-Eyes-Group is used to ensure that a cabinet lock can only be opened
when two different keys are held in front of it; one of them needs to be a member
of a Four-Eyes-Group while the other user has to be authorised for the cabinet
lock as usual. Which group is defined as the four-eyes group can be configured
for each cabinet lock.
By using the advanced setting options, one can allow the cabinet lock to be used
by keys, which do not have the authorisation or do not even belong to the locking
system (free selection of cabinet).
3.1.2
Time zone
You can restrict the locking access right in terms of time by using a time zone.
The time restriction along with the locking authorizations are programmed in the
key in the Clex prime system.
The following time restrictions are possible:
Total interval
Day interval
Weekly schedule
Holidays
Special time zones
For detailed information on the different time zones, please refer to the Keyvi
software manual.
3.1.3
Automatic expiry date
Using the automatic expiry date, it is possible to restrict the validity of a key
regardless of the time zones applicable for the key.
For detailed information on the automatic expiry date, please refer to the Keyvi
software manual.
3.1.4
Wireless network
If a corresponding wireless network is installed in the building, then the cabinet
lock CX6192 can be integrated with this network. The following functions can be
then be executed via radio:
Programming access rights
Changing access rights
Configuring time zones / timer circuits
Reading event log
Engaging the cabinet lock (for the duration defined by locking time)
Viewing battery and maintenance messages
Reading the battery value
FW update
3.1.5
Key feedback
Even for cabinet locks operated offline, there is an option to send the battery
status of the cabinet locks to the Keyvi management software. To do this, the
battery status of the 16 most recently operated locking units is stored on the key.
The battery status information is sent to Keyvi and deleted from the key if the key
is read by an automatic programming terminal or a programming station. A
prerequisites is that the key should have been prepared for writing the information
and the option
Key feedback
should be set in the cabinet lock.
Key Feedback
can only be used with the transponder types MIFARE
®
and LEGIC
®
advant.
Four-Eyes-Group
Advanced setting
options