UHP SCPC MODEM
USER MANUAL, v3.2
© ROMANTIS 2015
24
www.uhp.net
3.
SCRIPT-BASED CONFIGURATION
UHP router can be configured with scripts which are sets of commands containing the device settings. Commands
are transmitted as a single block and then are sequentially performed in the device.
Script-based UHP router settings allow quick configuration of local and remote hardware. To configure the remote
hardware, a satellite connection to the remote device is required. The script is sent in a single block which ensures
execution of all transmitted commands of the script regardless of their order in the script.
Script can be created in the following WEB interface sections:
1.
Select Setup via script in the Menu of commands;
A local device is configured in this section.
2.
Maintenance –> Network script
The following can be configured in this section:
Local router;
Remote router with a specified serial number;
Group of remote routers.
Remote routers script-based configuration requires at least a one-way communication channel from the router
sending script to the routers which are being configured.
Scripts allow configuring the following router settings:
Network settings;
Modulator and demodulator settings;
Configuration profiles settings;
Router SW loading settings.
The full set and description of the commands for a configuration script is available via help command from the
console application when the device is accessed via a USB connection or Telnet protocol.
See below (Table 1) an example with a list of commands to configure the router located on Station-1 side using
configuration scripts.
Table 1 Example of commands included into configuration script
Command
Description
ip address 192.168.0.1 255.255.255.0 1
Assign an IP address to Ethernet interface
ip address 192.168.11.1 255.255.255.0 1
Assign an additional IP address to Ethernet interface
ip map 192.168.1.0 255.255.255.0 ml 1 1 0 1
Create a default route with LOW priority, via SVLAN 1, to the
Station-1, without applying Traffic shaper, VLAN 1
svlan receive 2 1
Permit to receive traffic from SVLAN 2
demodulator lnb power off
LNB, 13.5/18 VDC power is off
demodulator reference off
LNB 10 MHz reference signal is off
modulator inversion off
Transmit spectrum inversion is off
modulator reference off
BUC 10 MHz reference signal is off;
modulator power off
BUC 24 VDC power is off,
rf lo 10000000 13050000
Assign a local oscillator (LO) to LNB and BUC respectively
profile 2 type auto scpc
Create a SCPC modem profile with number 2 and automated run
profile 2 rx 11018170 834
Configure the receive frequency and symbol rate respectively
profile 2 tx 14317373 1667 8
Configure the transmit frequency and symbol rate respectively
profile 2 tlc on 15 15
Activation of TLC with local transmit and remote receive levels
profile 2 acm on 19 1
Activation of ACM with max MODCOD=16APSK 3/4 and threshold
1 dB respectively