NO: Fail-Secure Lock NC: Fail-Safe Lock
Remark: Incorrect setting will affect operating of the lock, please con-
firm the lock type before setting.
3) Lock Type Select
Toggle: Press button A for ON, press button A again for OFF.
Latched: Press button A for ON, press button B for OFF.
Momentary: Press button A for ON, Release button A for OFF.
Remark: Latched is only valid when using a transmitter with 2-buttons.
4) Operating Mode Select
Support 0-15 seconds time delay.
Remark:
Only available when Momentary selected
.
5) Delay Time Setting
6
EN