LAS 260.1
– Date 07/2023
LED status messages
Page 39
Status orange
NOTICE
NOTICE
Warning
Flashing:
This status is only output in the operating mode ecoflow CS
®
.
The set suction power is not currently being attained by the
unit.
The device is running outside of the unit specifications.
•
Connect the suction section.
•
Reduce the diameter of the suction section.
•
Switch the control mode from high-pressure
operation to medium-pressure operation.
•
Check the suction power and slowly reduce it if
required via the potentiometer until the status
changes to green.
Continuously on:
Particulate filters are heavily saturated. The particulate filters
need to be replaced soon.
Get new filters ready for replacement.