24

 

Issue: 5 - 13/02/2019 
 

5. Important Safety Information 

 

Please read all instructions prior to using any Ultimate Healthcare supplied product. The Tamora Plus 

II dynamic mattress replacement system must be used in accordance with this User Manual. 

 

 

The mattress must only be operated by personnel who have been properly trained or have 

suitable experience with products of this nature. 

 

Ensure a clinical Risk Assessment is conducted, which should take account of the suitability of 

use of 

this product, patient’s condition, any ancillary equipment in use and the surrounding 

environment. This should include assessing the use of side rails, head and footboards etc. 

Pressure settings should be advised or prescribed by a medical practitioner. 

 

Only personnel trained or formally approved by Ultimate Healthcare in operation and 

maintenance of Ultimate Healthcare products may perform maintenance; modification or repair 

work on any Ultimate Healthcare supplied product. 

 

Ensure the power cable is not trapped or twisted and is routed suitably to avoid crushing or 

entrapment when connected to the product. 

 

Do not use your mattress system power unit in the presence of flammable gases. This excludes 

oxygen cylinders. 

 

Avoid hazards caused by inappropriate handling of the power cable e.g. by kinking, shearing or 

other mechanical damages. 

 

The power cable for this product must be unplugged from the mains power outlet socket and 

suitably stowed before moving, cleaning or maintenance activities. 

 

Do not secure mattress straps to removable head or footboards or any fixed (non-moving) parts 

of a profiling bedframe.

 

 

Disconnect from mains (power supply) before cleaning the power unit. 

 

When cleaning do not immerse the power unit in water.

 

 

Use only the cleaning and disinfectant agents recommended in this User Manual. 

 

When connecting product after transportation or storage, inspect the power cable visually for any 

signs of damage. If evident, do not use product and contact Ultimate Healthcare or your local 

distributor for repair.

 

 

When storing, ensure the product is stored away from direct sunlight and extreme cold conditions. 

 

Never block the air openings of this product or place it on a soft surface, such as a bed or couch, 

where their openings may be blocked. Keep the air opening free of lint, hair, and other similar 

particles. Air ventilation through the power unit is vital for correct and safe operation. 

 

If this product is used for any activity other than detailed within this User Manual then personal 

risk to the end user or patient may occur. Ultimate Healthcare shall not be held liable/responsible 

for such an event. 

 

Do not smoke, or allow the patient to smoke when using this product. Keep all possible ignition 

sources clear of this product 

Summary of Contents for Tamora Plus II

Page 1: ...Tamora Plus II Dynamic Mattress Replacement System UPRA367803 2 ________________________________________________ User Manual Issue 5 13 02 2019 UPRA367803 2 UM 5...

Page 2: ...Page 2 of 24 Issue 5 13 02 2019...

Page 3: ...level 11 8 2 Control panel lockout 12 8 3 Function mode switch 12 8 3 1 Alternate 12 8 3 2 Static 12 8 4 Alternate cycle time selection 12 8 5 Alarm mute 12 9 CPR Mode 13 10 Transport Mode 13 11 Alar...

Page 4: ...f the product 2 Intended Use The intended use of this product is to prevent and or manage pressure ulcers while optimising patient comfort for patients up to 200kg 31 5 stone 2 1 Contraindications The...

Page 5: ...e Management Fixings Air Pipe Connector 3 x Static Head Cells 13 x Standard Cells Removable Cover 2 Foam Base Compartment FOOT END HEAD END Knitted Cell Retention Bands Air Pipe Connection Point ON OF...

Page 6: ...that requires correct procedures or practises in order to prevent personal injury BF symbol indicates this product is according to degree of protection against electric shock for type BF equipment The...

Page 7: ...power cable e g by kinking shearing or other mechanical damages The power cable for this product must be unplugged from the mains power outlet socket and suitably stowed before moving cleaning or main...

Page 8: ...lassification Class II Type BF Warranty 2 years Operation environment 50C to 400C 15 RH 93 RH no condensation Storage environment 25 70 93 RH no condensation Environment pressure 70 kPa 101 3 kPa Wate...

Page 9: ...foot end as viewed from the foot of the bed There are security straps fitted to the base cover of the mattress which should be fastened loosely to convenient points on the bedframe patient surface Ca...

Page 10: ...pipe connector to the power unit and then ensure that the air tubes are free from any kind of obstruction and are not kinked Plug the power cable into a suitable electrical socket and switch ON using...

Page 11: ...within a safe pre set range to provide patients with enhanced comfort or support whilst maintaining a very good level of protection and therapy Qualified clinical advice must always be taken before a...

Page 12: ...d cycle time until another mode is selected 8 3 2 Static Pressing the Mode button until the Static indicator illuminates puts the system into Static mode Within this mode the mattress will maintain a...

Page 13: ...r pressures in the mattress will now equalise but maintain a degree of comfort This will maintain the cells in their present state for approximately 48 hours It is important to restore the Tamora Plus...

Page 14: ...that the mains switch is turned ON Check power unit for any blown fuses Low Pressure indicator is flashing and sounding Check to ensure that the CPR tag is securely fitted in place Check whether powe...

Page 15: ...unit in water Caution When cleaning disinfecting ensure that only a damp cloth is used Caution After cleaning dry the mattress out of direct exposure to sunlight Caution Using inappropriate detergent...

Page 16: ...le dried or air dried They may be tumble dried on a low heat for up to 90 minutes Drying temperature must not exceed 400C The mattress cover and mattress must be dry prior to refitting Caution Exceedi...

Page 17: ...or break For replacement please contact Ultimate Healthcare or your local distributor 15 2 Fuse replacement 1 Disconnect the plug from mains power when a blown fuse is suspected 2 Remove the cover of...

Page 18: ...Page 18 of 24 Issue 5 13 02 2019 16 EMC Information...

Page 19: ...Page 19 of 24 Issue 5 13 02 2019...

Page 20: ...Page 20 of 24 Issue 5 13 02 2019...

Page 21: ...Page 21 of 24 Issue 5 13 02 2019...

Page 22: ...Page 22 of 24 Issue 5 13 02 2019 Notes...

Page 23: ...Page 23 of 24 Issue 5 13 02 2019 Notes...

Page 24: ...ue 5 13 02 2019 Ultimate Healthcare Ltd Calmore Industrial Estate Nutwood Way Totton Southampton Hampshire SO40 3WW Tel 0333 321 8996 Fax 023 8066 2388 Email info ultimatehealthcare co uk www ultimate...

Reviews: