Table 5. Remote Programming Mode Commands - Continued
OP
CODE
(HEX)
MNEMONIC/DESCRIPTION
COMMAND/ACKNOWLEDGEMENT
A1
MACROP
Download macros for prefix/suffix.
COMMAND: A1aCxDx.......<CR>
A1
= Op Code
a
= macro to load in ASCII
range A-Z listed below
Cx
= key number
(refer to Appendix D)
Dx
= key number
(refer to Appendix D)
<CR> = terminate command (0D hex)
A
= AUX serial port prefix
B
= AUX serial port suffix
C
= keyswitch 1 make
D
= keyswitch 1 break
E
= keyswitch 2 make
F
= keyswitch 2 break
G
= keyswitch 3 make
H
= keyswitch 3 break
I
= mag 1, 3 prefix
J
= mag 1, 3 suffix
K
= mag 1, 3 field separator
L
= mag 2 prefix
M
= mag 2 suffix
N
= mag 2 field separator
O
= cash drawer 1 closed
P
= cash drawer 1 open
Q
= cash drawer 2 closed
R
= cash drawer 2 open
S
= bad read track 1-3
T
= bad read track 2
U
= account separator 1-3
V
= main serial port prefix
W
= main serial port suffix