background image

5

UNPACKING

 

Remove the 

Ultimate

TM

 Ultraviolet Water Purifier from its shipping carton. 

 

Atlantic Ultraviolet Corporation

®

 takes all possible precautions when packaging this unit to prevent damage. Carefully 

inspect the disinfection chamber, lamp cable, lamp connection, power cord and plug for damage, report all damage 
immediately. Do not assemble or operate if there is any damage, visible or suspected.

 

Germicidal lamp is packed separate in a cardboard tube, to ensure maximum protection in shipping. Keep aside until ready 
for installation.

 

Quartz sleeve is packed separate in a cardboard tube, to ensure maximum protection in shipping. Keep aside until ready for 
installation.

 

Carefully inspect all packing materials to prevent the loss of accessories, mounting hardware, and spare parts.

 

Do not discard packing materials until unit is assembled and check out is complete.

INSTALLATION

l

oCation

1.  The water purifier is intended for indoor use only. The water purifier is designed to mount vertically. The water purifier 

should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area 
surrounding the water purifier, should be between 35

o

 F and 100

o

 F.

2.  The water purifier must be connected to the cold water line only. Inlet water temperature should not exceed 100º F.

3.  Electrical power supplied to the water purifier 

MUST

 match power requirements listed on the water purifier. Use of a voltage 

surge protector is recommended.

4.                         Install water purifier within 48” of a known good ground. Water Purifier will need to be installed into approved 

ground fault circuit interrupt (GFCI) receptacle.  Where a 2-prong or unprotected 3-prong receptacle is encountered, it must 
be replaced by a properly grounded Ground Fault  Circuit Interrupt (GFCI) receptacle. Installation must be in accordance 
with the National Electrical Code and any local codes and ordinances by a qualified electrician.

5.  The water purifier should be located in a dry, well-lit area, which provides enough room to perform routine maintenance. 

The 

Ultimate

TM

 is designed to mount in a vertical position, with the gland end up. Unit must be mounted to a secure wall or 

structure using the brackets provided.  It is not recommended to have the unit solely supported by the plumbing to the unit. 
(The quartz sleeve and lamp are removed from the gland end.) Allow a service area of at least one chamber length from the 
gland end, for replacement of the lamp or cleaning/replacing quartz sleeve, as well as a minimum of 6” on the opposite end of 
the water purifier. Minimum clearance to the floor 18’’

6.  Choose a location for your 

Ultimate

TM

  unit that is isolated from vibration. Vibration will damage lamp and lead to 

premature system failure.

7.  The water purifier should be located closest to the point of use. This eliminates the possibility of purified water being          

re-contaminated by bacteria in the water distribution system after purification.

8.  If your system is subject to water hammer conditions, it is recommended that you install a water hammer suppressor. Water 

hammer may cause damage to the O-Ring seal.

9. 

                     

 As with any water handling device, the purifier should be located in an area where any possible condensation or 

leakage from the purifier, accessories and/or plumbing will not result in damage to the purifier or to the area surrounding the 
purifier. 

For added protection, it is recommended that a suitable drain pan be installed under the purifier. The drain 

pan must be plumbed to an adequate, free flowing drain to prevent water damage in the event of a leak. There are 
numerous leak detection/flood stop devices, available on the market today, designed to stop the flow of water, reducing 
the chance of water damage due to leakage. For more details regarding leak prevention and/or limiting damages due 
to leaks, please contact the factory.

 

(Continued on Page 6)

The 

Ultimate

TM

 Ultraviolet Water Purifier includes:

 

1 - Disinfection Chamber

 

1 - 

STER-L-RAY

 

®

 Germicidal Ultraviolet Lamp

 

1 - 

Surelite

®

 Ballast manufactured for 

Ultimate

TM

 

1 - 

CRYSTAL CLEAR

TM

 Quartz Sleeve

 

1 - O-Ring

 

1 - Teflon

®

 Washer

 

1 - 

Promate

TM

 Static Gland Nut

 

2 - Mounting Brackets (Upper & Lower)

 

1 - Bracket Nut

 

1 - Owner’s Manual

 

1 - Grounding Kit

Summary of Contents for U4

Page 1: ...017 2017 Atlantic Ultraviolet Corporation ASSEMBLED IN THE USA Read and Follow All Safety Instructions Save These Instructions Installation Operation Maintenance Models U4 U7 U9 U15 Extensive Product...

Page 2: ...ntenance of the UltimateTM line of water purifiers Models U4 U7 U9 and U15 Questions that are not specifically answered by these instructions should be directed to the Factory Atlantic Ultraviolet Cor...

Page 3: ...Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the water purifier 15 SAVE THESE INSTRU...

Page 4: ...oorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The LED indicator light located on the ballast and the translucent plug on top of chamber provides visual indication of ge...

Page 5: ...s enough room to perform routine maintenance The UltimateTM is designed to mount in a vertical position with the gland end up Unit must be mounted to a secure wall or structure using the brackets prov...

Page 6: ...ia in any of these units 11 Flow direction water enters the unit through the lower fitting and exits through the upper fitting The flow control is mounted in the lower inlet fitting 12 Installation re...

Page 7: ...k 5 Pump 6 Reverse Osmosis 7 Prefilters Cold Water Line Ultraviolet Water Purifiers should be installed closest to the point of use POU 5 Micron Filter Valve Union Elbow Elbow OPTIONAL EQUIPMENT Flow...

Page 8: ...p 5 Place Teflon washer over quartz sleeve until it rests on O Ring Step 7A Insert the lamp part of the way into the disinfection chamber Step 9 Thread translucent sight port plug into static gland nu...

Page 9: ...leeve parallel to the chamber Angling the quartz sleeve in any direction could result in the breakage of the quartz sleeve 4 Place the O Ring over the end of the quartz sleeve and push the O Ring down...

Page 10: ...ction is correct Installation 1 Wrap the copper strap tight around the pipe and line up the strap end hole with another hole on the copper strap as well as a hole on the brass colored S clip 2 Pull st...

Page 11: ...Sleeve Exploded View Always disconnect power to the unit before performing any service or maintenance Lamp and quartz sleeve are easily damaged Exercise care when removing or replacing 1 Disconnect p...

Page 12: ...tz sleeve with the gland fitting of the chamber 10 Carefully slide the quartz sleeve into the chamber guiding it through the gland fitting until it seats into bottom center of water purifier NOTE Use...

Page 13: ...ant visual monitoring of normal operation In the event of ballast or lamp failure the safety sensor indicates an alarm condition The safety sensor is capable of operating an optional audio alarm and o...

Page 14: ...the ballast s lamp out protection will prevent the ballast from operating and a red LED light will illuminate and audio alarm will sound To reset disconnect the ballast from power and reconnect or re...

Page 15: ...9A 00 0229A 00 0229A 5 O Ring Buna N 1 00 8300A 00 8300A 00 8300A 00 8300A 6 Bracket Nut 1 25 8106B 25 8106B 25 8106B 25 8106B 7 CRYSTAL CLEARTM Quartz Sleeve 1 15 8110A1 15 8110A2 15 8110A3 15 8110A4...

Page 16: ...been made to determine the patent status of applications illustrated or described in this publication Inclusion in this publication of any design or method of use which may be patented is not to be c...

Reviews: