Positioning the RecoupAerator
We recommend the RecoupAerator be mounted in a conditioned space, as
this will affect the performance and longevity of the unit. If the
RecoupAerator is installed in an unconditioned space, the section(s) of
inside ducts, and possibly the unit itself may need to be insulated from the
unconditioned environment.
Position the RecoupAerator in a location convenient to existing
ducting. If possible, locate equipment away from the quiet rooms (e.g.,
bedrooms). Avoid directly suspending the RecoupAerator from the mid-
span area of joists. This can result in structural vibration. Allow adequate
space for maintenance and service of the RecoupAerator.
Vertical/Wall
Top and Bottom Exhaust shown
Top Exhaust
Bottom Exhaust