Ultimatte-9 Operations Manual
March 1, 2000
80
Figure 37: Miscellaneous Configure Menu
XXXIV. MISCELLANEOUS CONFIGURE MENU
1. GPI Out Save
When selected, saves GPI Output (1 or 2) settings with the file.
2. Control Knob Detents
Adjusts software detent, or dead spot, at default position on Control Knobs.
Detent Short sets a short detent.
Detent Long sets a longer detent.
Detent Off disables detent.
Note: Master Control Knobs will not be affected by detent selection.
3. Rehearse Mode
When a unit is selected to be ON AIR, all functions that were designated as ON AIR LOCKOUT
will not be available to the user. During rehearsal times, the user may choose not to lockout the
designated functions, in order to make adjustments to the units. In this situation, instead of
removing individual ON AIR LOCKOUT restrictions from individual controls and buttons, enabling
the REHEARSE MODE will bypass the lockout. When rehearsing is over and the unit will actually
go on air, the REHEARSE MODE is disabled to restore all designated lockout functions.
4. Font Percent
Changes size of percent display text, large or small.
5. Filter On
Enables or disables the use of the FIR filters in the Color Space Converters
.
6. Editor 115.2K
Select Editor baud rate between 38.4K and 115.2K
Online [ 1, 2, 3, 4 ] Active ( 2 ) FILE=
RETURN
UM9-
Miscellaneous Configure Menu
GPI
SETUP
GPI I / O
CONFIGURE
INPUT
CONFIGURE
GPI OUT
SAVE
DETENT
SHORT
REHEARSE
MODE
FONT LARGE
PERCENT
FILTER
ON
EDITOR
115.2K
ON AIR
LOCK OUT
(COLOR) BACKING